How to Program the Unit
For the Alertex system to work correctly, the units need to be on the same
Site and Subnet but have unique Unit numbers. Use the pink buttons in
the lower right corner of the PCB to program the unit.
*Each unit must have a
different unit number
1. Press and hold Select until the LED screen displays - - at the top of
the screen
2. Press Select to first change the SITE value
3. Use the Up and Down buttons to change the SITE value (SI)
4. Press Select again to save the value and move on to the SUBNET
value (SU)
5. Use the Up and Down buttons to change the SUBNET value
6. Press Select again to save the value and move on to the UNIT value
(UN)
7. Use the Up and Down buttons to change the UNIT number value
8. Press Select again to save the value and move on to the CALL REPEAT
value (Cr)
9. Use the Up and Down buttons to change the CALL REPEAT value
10. Press Select again to save the value and move on to the CALL PERIOD
value (CP)
11. Use the Up and Down buttons to change the CALL PERIOD value
12. Press Select again to save the value and move on to the MASTER
UNIT value (MU)
13. Use the Up and Down buttons to change the MASTER UNIT value
14. Press Select again to save the value and move on to the TIME SET
value (ts)
15. Use the Up and Down buttons to change the TIME SET value
16. To save the values, press and hold the Memory button until the LED
screen displays - - at the bottom of the screen
M
LED Screen
Select
Memory
Down
Up