2. INSTALLATION
2.1 Mounting the device
RACK MOUNT
In case you want to mount your GigaCore 26i and GigaCore 26i
with PoE in a standard 19-inch rack, you need 4 rack screws to
mount the device.
2.2 Power up the device
Power-up the device with a power cable with IEC connection (J)
(please contact your local dealer if you don’t have a suitable power
cable on hand). The device will automatically switch on. To shut it
down after use, just un-plug the power cable again.
After connecting the power cable correctly, the power LED
indicator on the front panel will light up green.
The GigaCore 26i and GigaCore 26i with PoE requires standard AC
power distribution from 100-240VAC, 50/60Hz. Current required
depends on the model.
Please use an IEC plug compliant cable to power the device.
Luminex recommends the use of a power cable fi tted with a
locking mechanism to ensure a reliable connection to the device.
When installing a new connector please refer to the following wire
colour code reference:
WIRE*
CONNECTION
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
* International (Harmonised) Standard
J
6