The DMX outputs can be connected directly to the lighting devices which will be controlled, it can also be 
used as a splitter or buffer for the DMX signal in case more than 32 lighting devices are connected in a 
DMX output; 

 

The power comes through a socket, the power supply works with 110 or 220V, it is not necessary to 
select the tension, the power supply is automatic; 

 

The Ethernet connection: 

o

 

can be connected directly to the network card from the computer through a cable; 

o

 

can be connected to a Ethernet switch in case of more interfaces or other devices in the same 
network; 

o

 

can be connected to an access point or router (wireless) allowing wireless communication; 

To connect more than one interface on the same network, the IPs must be changed, below there is an example 
of a connection of 2 or more interfaces on the same network: 

 

Note that the second interface has a different IP address than the first interface, always use different IP 
addresses.The computer is in the same network class as the interfaces (class C – 192.168.XXX.XXX). 

 

6.

6.

6.

6.

 

Program recording in the P

Program recording in the P

Program recording in the P

Program recording in the Pen Drive

en Drive

en Drive

en Drive    

In the Lumikit PRO X4 interface it is possible to connect a Pen Drive in the USB port, this Pen Drive can be used 
to record up to 20 programs, each program can have at most 30 minutes of Art-Net signal at 25 FPS.  

Summary of Contents for PRO X4

Page 1: ...USE THE PRODUCT READ THE MANUAL BEFORE USE THE PRODUCT READ THE MANUAL BEFORE USE THE PRODUCT User manual User manual User manual User manual Lumikit PRO X4 interface Lumikit PRO X4 interface Lumikit...

Page 2: ...tor and 1 2W or 1W different values can be terminator resistor consists in a 120 ohms resistor and 1 2W or 1W different values can be tested connected between the pin 2 and 3 of the DMX connector conn...

Page 3: ...THE PEN DRIVE 17 6 5 DELETING PROGRAMS FROM THE PEN DRIVE 17 7 7 7 7 FIRMWARE UPDATE FIRMWARE UPDATE FIRMWARE UPDATE FIRMWARE UPDATE 18 18 18 18 8 8 8 8 REMOTE REMOTE REMOTE REMOTE CONTROL FOR ANDROID...

Page 4: ...ry It is also possible to connect multiple interfaces in the same network For example to illuminate an avenue passing DMX signal through long distances is an issue a solution would be to spread interf...

Page 5: ...4 5x17x11 7 cm Weight 650g 950g with cables and package Plastic box with plugs for power supply cables connection DMX signal and Ethernet network Lumikit PRO X4 RACK specific features 1500Vrms insulat...

Page 6: ...Art Net mode and if pressed together with the PLAYBACK SAVE CONFIG button starts the record on Pen Drive f PLAYBACK SAVE CONFIG button sets the interface in playback mode reproduces programs recorded...

Page 7: ...Art Net setting shown below 3 1 C 3 1 C 3 1 C 3 1 Change the hange the hange the hange the interface interface interface interface IP IP IP IP address and universe address and universe address and uni...

Page 8: ...by the DMX outputs 3 After making the necessary changes click Reprogram interface 4 and follow the given instructions With this procedure the reprogramming will be complete In case the interface does...

Page 9: ...red on the interface do the RESET of the interface Chapter 5 this procedure allows quick configuration of the IP address of the interface By default the interface comes standard with the IP 192 168 0...

Page 10: ...r setting is used for example if interface is configured for only 1 universe fill 1 in this field g In field DMX Universe fill 0 unless another initial DMX universe is used anyway it also can be adjus...

Page 11: ...e interface must have an must have an must have an must have an IP IP IP IP 192 168 0 192 168 0 192 168 0 192 168 0 ranging ranging ranging ranging from from from from 1 1 1 1 until until until until...

Page 12: ...s responding at some point in this case it is better to use lower values 3 3 3 3 3 3 3 3 Network Network Network Network speed speed speed speed 10Mpbs 100Mbps Fast Ethernet 10Mpbs 100Mbps Fast Ethern...

Page 13: ...utton for at least 15 seconds when turning the interface on When in reset mode it is possible to easily choose between the following IP addresses by pressing the RESET CHANGE IP button IP address 192...

Page 14: ...ase of more interfaces or other devices in the same network o can be connected to an access point or router wireless allowing wireless communication To connect more than one interface on the same netw...

Page 15: ...ected to the interface this is normal therefore it is recommended to connect the Pen Drive is recommended to connect the Pen Drive is recommended to connect the Pen Drive is recommended to connect the...

Page 16: ...in this case the file will have approximately 90MB Since the interface supports up to 20 programs a 2GB Pen Drive is enough to store all programs 6 3 6 3 6 3 6 3 Recording Recording Recording Recordin...

Page 17: ...than one program inside the Pen Drive the next program will be reproduced by pressing the button PLAYBACK SAVE CONFIG again The program reproduction can be also be made through the remote control app...

Page 18: ...wn after the interface identification in the example LUMIKIT PRO X4 version 10 V10 Do not attempt to change the lkprox4 cry file do not use files from other suppliers under the risk of Do not attempt...

Page 19: ...rams in the Pen Drive will be shown at the upper corner it is possible to see the option to delete programs from the Pen Drive and an option to make a new recording When selecting the recording option...

Page 20: ...ent network than the interface Even if the interface is not shown in the list it is possible to use the BROADCAST mode this mode send the commands to all network In BROADCAST mode it is not possible t...

Page 21: ...h lation with an opto an opto an opto an opto coupler coupler coupler coupler in in in in the logic circuit output the logic circuit output the logic circuit output the logic circuit output 10 1 Lumik...

Page 22: ...10 10 10 10 3 Grounding 3 Grounding 3 Grounding 3 Grounding It is recommended to use installations with grounding The The The The GROUND pin of the GROUND pin of the GROUND pin of the GROUND pin of th...

Page 23: ...y for Pen Drivers usage The USB port in this interface was projected only for Pen Drivers usage The USB port in this interface was projected only for Pen Drivers usage The USB port in this interface w...

Page 24: ...step tutorial on how to make the IP configuration on Windows 7 e 8 In Windows 7 click on start or in Windows 8 on the home screen search for Control Panel Click Network and Internet Click Network and...

Page 25: ...IP address MACOSX MACOSX MACOSX MACOSX To establish the initial communication with the interface configure your computer s network adapter to the IP 192 168 0 30 because this IP is from the same class...

Page 26: ...interface in this case use a fixed IP Turn off other network adapters If using WINDOWS check the firewall initially turn the firewall off completely if it works create a rule for Lumikit software Q Th...

Reviews: