The most common is to measure the water level before and after the coarse grille and the fine grille at
the water inlet of the sewage treatment plant to calculate the height difference between the water
levels. There are also installations before and after the gate, measuring the water level difference
before and after the gate to determine the time to open the gate.
Ultrasonic level difference meter (material level, liquid level) is used to measure the difference
between the liquid level or material level of two different containers.
There is also not to measure the liquid level difference, but to measure the water level of the two pools,
and then output 2 4-20mA.
1.Use
2.The Main Technical Indicators
Dusty
Normal range
Special range
measurement accuracy
Resolution
display
Analog output
Relay output
powered by
Surroundings
temperature
Communication
Protection class
Probe cable
Probe installation
5 meters, 10 meters, 15 meters, 20 meters
30 meters, 40 meters, 50 meters, 60 meters
0.5% -1.0%
3mm or 0.1% (whichever is greater)
12864 Dot Matrix Chinese LCD
Two 4 ~20mA / 510Ω loads
4 AC 250V / 8A or DC 30V / 5A state programmable (optional)
220V AC + 15% 50Hz or 24VDC 120mA optional
Display instrument IP65, probe Ip68
10 meters standard, up to 200 meters (requires shielding of all electromagnetic Int-
erference), and In the same trunk as any AC power cable.
Selection based on range and probe
Split type
Display instrument (transmitter) -20 ~ + 60 ℃,
Probe (sensor) -20 ~ + 80 ℃
485 communication (optional)