Other measuring instruments can also be used, such as radar level gauges or magnetostrictive level
gauges.
① Bubbles: If the bubbles on the surface of the medium are large and the bubble layer is thick, it will
cause measurement errors and may not even receive the reflected ultrasonic waves. Take measures
to prevent air bubbles, or install the sensor in the bypass pipe for measurement.
4.3.3.2 Common installation errors
②
The sensor is installed in the wrong direction
If the sensor is not installed on the surface of the medium, the measurement signal will be weakened.
To ensure the best measurement results, please align the axis of the sensor with the surface of the
medium, which is perpendicular to the surface of the interface to be measured.
Where bubbles are generated
The sensor probe should be perpendicular to the surface of the medium