VDSL LIM physical description
VDSL LIM Hardware
1 - 4
Lucent Technologies
363-217-032R9.9.0
Issue 2, March 2006
Status light indications
When lit, the status lights on the VDSL LIM, displayed in
, have the following
indications:
Important!
These status lights illuminate briefly during startup or restart, then
remain dark until the module passes its power-on self test (POST). When the module
passes the POST and becomes operational, the ACTV (active) light illuminates.
Line protection
Currently, VDSL LIMs are not available with integrated line protection hardware. A
separate line protection module (LPM) is required for each installed VDSL LIM.
Light
Color
Indication
1
FAULT
Orange
The module failed to pass its POST.
2
ACTV
Green
The module or port is fully operational and no
errors have been detected.