Acceptance: DLP-503
363-205-401
Page 2 of 2
Issue 7, March 1997
2.
Verify that AC power outlet enclosure is an approved lockable enclosure.
3.
Verify that AC power outlet has been wired to an electrical circuit breaker; not
to a ground fault circuit interrupter (GFCI).
4.
Is 120 V AC present at AC outlet?
If YES, then proceed to Step 8.
If NO, then continue with Step 5.
5.
Is circuit breaker that is providing power to AC outlet turned on?
If YES, then proceed to Step 6.
If NO, then continue with Step 7.
6.
Resolve problem through local procedures.
7.
Turn circuit breaker that is providing power to AC outlet to on position and
repeat from Step 4.
8.
Verify that ground cable to 900A1 DT closure is secured by SLU35 connector
(cable clamp) located in bottom of DT closure and that ground cable is routed
and terminated to an approved ground connection.
9.
Verify that NIU is grounded per instructions for the type of NIU being used.
10. Verify that fiber drop is terminated with an
ST
u
d
lightguide cable connector that has
been attached to optical unit backplane coupler. Also verify that excess fiber cable is stored in
fiber retaining bracket.
11. Verify that fiber drop, including metal shield, is securely fastened to wire clamp
and the wire clamp is securely attached to ground bracket in bottom of 900A1
DT closure.
12. Verify that copper pairs from 900A1 DT closure to NIU have been installed.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.