RT Turn Up: DLP-519
363-205-401
Page 2 of 4
Issue 7, March 1997
8.
NOTE:
The remainder of this check is valid only for banks equipped with
MC97723A1, MC97756A1, MC97771A1 , MC97776A1 (Feature
Package C-AutoCut and Feature Package B Mode 2 only), or
MC97779A1 (Feature Package F AutoCut and Mode 2 only) coded
BCUs.
If RT is equipped with the MC97724A1 BCU, proceed to Step 17. Otherwise
continue with this Step. Locate, using CO or engineering records, points where
MISC1 and MISC2 remote alarms are activated.
9.
Activate MISC1 remote alarm.
10. Is MISC1 indicator on BCU lighted?
If YES, then proceed to Step 12.
If NO, then continue with Step 11.
11. Check wiring using SD-7C118-01 or SD-7C118-02. Repeat procedure from
Step 9 after locating and correcting trouble.
12. Deactivate MISC1 remote alarm and activate MISC2 remote alarm.
13. Is MISC1 indicator on BCU off and MISC2 indicator on BCU lighted?
If YES, then proceed to Step 15.
If NO, then continue with Step 14.
14. Check wiring using SD-7C118-01 or SD-7C118-02. Repeat procedure from
Step 9 after locating and correcting trouble.
15. Deactivate MISC2 remote alarm.
16. Verify that MISC2 indicator on BCU goes off.
17. Is system equipped with the Fiber-To-The-Home feature?
If YES, then continue with Step 18.
If NO, then proceed to Step 321.
18. At optics power shelf assembly, replace fuse in CMN fuse holder with blown
fuse in BFU3 (if equipping the lower dual bank assembly) or BFU4 (if equip-
ping the upper dual bank assembly).