363-205-401
RT Turn Up: Introduction-000
Issue 7, March 1997
Page 1 of 2
Turn Up Series 5 RT Channel Bank
Introduction
This Tab provides procedures to equip and turn up the blue, white, or both systems of
the
SLC
Series 5 carrier system remote terminal (RT) dual channel bank assembly.
The procedures include installation of common circuit packs optioned for preservice.
These procedures assume the
Acceptance Tab procedures have been done, and the
Power Up Tab procedures have been done to turn up the power plant and ringing
generators.
This Tab also provides procedures to add digroups CD to an in-service system.
When adding digroups CD to a system, you may have MN (minor) and NE/FE (near
end/far end) alarms until both CO and RT ends of the system have been equipped
and optioned for digroups CD.
Feature Packages
The
SLC Series 5 carrier system offers a variety of system configurations offering
POTS only, special services, concentration, and integration. These configurations are
called feature packages. The feature package is selected by the choice of bank
control unit (BCU), alarm display unit (ADU), and option settings on the ADU. The
choice of supporting common units [transmit/receive unit (TRU), line interface unit
(LIU), channel test unit (CTU), digital test unit (DTU), line switch unit (LSU), and
transcoder unit (TCU)] is determined by the feature package configuration.
Fiber to the Home (FTTH) arrangements are supported by Feature Package B (FPB)
with the MC97771A1 or MC97776A1 BCU, Feature Package C (FPC), or
FPC-AutoCut central office terminal (COT) and RT configurations with J1C182AE RT
channel bank. The Multi-Services Distant Terminal (
SLC
-2000 MSDT) is supported
by Feature Package F (FPF) using the MC97779A1 BCU, and provides the same
service capabilities FPC. The procedures to equip the FTTH DT equipment are found
in the
DT Turn Up Tab. Procedures to equip the MSDT equipment is found in
363-205-004.
These procedures assume the feature package configuration is known before circuit
packs are installed.