255-700-025
C-9
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
Appendix C Configuring In-Band Management
Using the Routed Connection Configuration
For setting up an in-band connection from the DS3 card to the CPU module,
configure the DS3 card and put it into service. Then, using the console
interface
[Connection Configuration]-> [In-Band Management IP PVC]
-> [Add Connection]
screen, configure the PVC to the FORECARD.
Example:
Slot<Slot> VPI:VPIabIP Address: 020.001.000.000
Port1
VCI:VCIabIP Mask: 255.255.000.000
Channel 1
Slot<Slot> VPI: VPIaxIP Address: 020.002.000.000
Port1
VCI: VCIaxIP Mask: 255.255.000.000
Channel 1
10
Set up in-band management connections on the CPU module of Node B:
Example:
Slot<Slot> VPI: VPIabIP Address: <NMS net. addr>
Port1
VCI: VCIabIP Mask: <NMS net. mask>
Channel 1
Slot<Slot> VPI: VPIbcIP Address: 020.001.001.000
Port1
VCI: VCIbcIP Mask: 255.255.255.000
Channel 1
Slot<Slot> VPI: VPIbdIP Address: 020.001.002.000
Port1
VCI: VCIbdIP Mask: 255.255.255.000
Channel 1
11
Set up in-band management connections on the CPU module of Node C:
Example:
Slot<Slot> VPI: VPIbcIP Address: <NMS net. addr>
Port1
VCI: VCIbcIP Mask: <NMS net. mask>
Channel 1
Slot<Slot> VPI: VPIceIP Address: 020.001.001.003
Port1
VCI: VCIceIP Mask: 255.255.255.000
Channel 1