Issue 5 November 2000
363-206-208
End-To-End Installation Tests for Ring Applications of the DDM-2000 OC-12 Multiplexer
Lucent Technologies - Proprietary
See Notice on first page
(4) For Release 5 applications, issue the
rtrv-fecom;
command to verify User Side
(us) and Network Side (ns) settings for each address occupied by an OLIU per
the following table:
If settings differ from the default values shown in the table, use the
set-fecom
command to change them to the values shown.
NOTE:
User Side (us) and Network Side (ns) settings for DDM-2000 OC-3 shelves, opti-
cally connected to the OC-12 shelf function units, must be set as follows:
(5) Enable Far End Communications for the Main-B-2 OLIU at the first node using
the
set-fecom:dcc-mb2:com=enabled;
command.
If this shelf has function unit OLIUs that have previously been optically con-
nected to DDM-2000 OC-3 shelves, enable communications between those
shelves also as follows:
Issue the
set-fecom:dcc-
address
:com=enabled;
command at the OC-12 shelf
for the function unit addresses of those OLIUs, and then at the OC-3 shelf for the
Main OLIU addresses.
Address
US/NS Setting
dcc-mb1
us
dcc-mb2
ns
0x1
Applications
1+1
Applications
dcc-a1
dcc-a
ns
dcc-a2
-
us
dcc-b1
dcc-b
ns
dcc-b2
-
us
dcc-c1
dcc-c
ns
dcc-c2
-
us
dcc-d1
dcc-d
ns
dcc-d2
-
us
Address
US/NS Setting
OC-3 Release 8
OC-3 Release 7 or
9
dcc-m
dcc-m1
us
dcc-m2
ns
dcc-a
dcc-a
ns
dcc-b
dcc-b
ns
dcc-c
dcc-c
ns
Summary of Contents for DDM-2000 OC-12