Installation Requirements
The ideal mounting position for the THERMASTRIP is on the ceiling, directly above the area to be heated. If this is not possible,
THERMASTRIP can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of
2.1m to 2.7m and the table is within 2.5m of the wall.
For mounting heights more than 2.7m, we recommend the use of the optional accessories to reduce the height of the heater to
2.3m
—2.5 m. This will increase the effectiveness of your THERMASTRIP. Refer to the Mounting Accessory section for more
information.
Electrical connections/GPO’s should not be located at the back of the heater. They should be located outside the physical footprint of
the units to minimize heat build-up behind the units.
If the heater is to be mounted on an incline (e.g. Vaulted ceiling), ensure the electrical connection is located at the lowest point of the
heater.