Safety 

THERMASTRIP has an IP rating of 55. This means it is safe for water ingress from all directions. The THERMASTRIP can be safely 

hosed down. Do not use high pressure water to clean heaters, light water spray only.   

Please refer to the maintenance section in this instruction manual. 

THERMASTRIP has undergone extensive testing both in laboratory conditions, the manufacturing facility in Melbourne and field trials 

in Australia and overseas. It has been this testing that gives the purchaser the confidence of a high quality product. 

 

Independent laboratory testing has confirmed full compliance with Australian and other International Standards.   

This includes CE, AS/ANZ, UL/CSE 

 

The heater comes in both plug (1500W, 1800W, 2400W) and hardwired (3200W) versions. In both cases the fixed wiring must be 

installed by a licensed electrician in accordance with the relevant wiring regulations. 

 

The THERMASTRIP is Class 1 equipment and must be earthed. 

 

In operation, this heater is VERY HOT

— do not touch any part of the heater while it is turned on. Do not touch any part until 30 

minutes after it is turned off. 

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or 

lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised to ensure they do not play with the appliance. 

 

Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the heater. 

If installed in wet areas, the heater switches or controls must be located so that they cannot be touched by persons in the bath or 

shower. 

 

The heater needs to be installed as per the installation instructions paying special attention to the minimum clearances. 

The heater needs to be mounted on a rigid bracket or fixing. 

The heater must not be mounted immediately below or in front of a socket outlet. 

The heater MUST NOT be placed close to curtains or other combustible materials. 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to 

avoid a hazard. 

An all-pole disconnection switch MUST be incorporated into the fixed wiring in accordance with the wiring rules. 

WARNING: FOR SAFE USE OF THIS HEATER AN ALL-POLE 

DISCONNECTION SWITCH MUST BE INCORPORATED INTO THE 

FIXED WIRING. 

This is in accordance with the latest wiring standards. 

Please note warranty will be void if installed without an all-pole disconnection switch.

 

 

This appliance, under no circumstances, is to be covered with insulating material or similar material. 

In case of a heater fault or damaged supply lead, the appliance should be returned to the point of purchase for return to Lucci for 

repair. 

Summary of Contents for THERMASTRIP 200060

Page 1: ...LUCCI THERMASTRIP INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND HEATER OPERATION...

Page 2: ...onnection Lay out all the components on a smooth surface and make sure there are no components missing If parts are missing return the complete product to the place of purchase for inspection or repla...

Page 3: ...cts in their path Discrete stylish heating for undercover outdoor and indoor open areas Using the radiant heating principle THERMASTRIP can provide effective and energy efficient comfort heating for u...

Page 4: ...tralian made Designed engineered and assembled in Australia the THERMASTRIP is fully backed by a 24 month warranty Stylish design The Heater that is a Design Feature The attractive THERMASTRIP comes w...

Page 5: ...Installation Instructions 5 P a g e v 1 0 Specifications Australia...

Page 6: ...outdoor tables BBQ s lounges assembly lines or indoor workstation Often it is more practical and efficient to spot heat these areas Spot heating will help to reduce the initial capital cost as well a...

Page 7: ...nd directly under the heater and the temperature decreases as you move away from the heater It highlights the importance of maintaining recommended mounting heights and if possible positioning the hea...

Page 8: ...ethod is to spot heat a table or similar area The below diagrams provide an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings Se...

Page 9: ...ounting heights more than 2 7m we recommend the use of the optional accessories to reduce the height of the heater to 2 3m 2 5 m This will increase the effectiveness of your THERMASTRIP Refer to the M...

Page 10: ...Installation Instructions 10 P a g e v 1 0 Installation location the below diagrams confirm the minimum recommended clearances...

Page 11: ...For other more challenging locations there are a range of mounting options available refer to below diagrams The THERMASTRIP can be mounted directly to the ceiling angled downwards on a wall attached...

Page 12: ...2 P a g e v 1 0 Standard Mounting Brackets The THERMASTRIP comes with a pair of standard mounting brackets These adjustable brackets allow direct ceiling or wall mount and come with preset angle optio...

Page 13: ...den beams rafters poles umbrellas struts etc Screws for connection to the beam or pole are not included Minimum pole diameter 20mm Maximum pole diameter 70mm This mounting option is suitable for umbre...

Page 14: ...the ceiling height is more than 2 7m is an enclosed outdoor environment or 2 5m in an exposed site it is recommended to lower the heaters to an ideal mounting height of 2 3m 2 5m The bracket is desig...

Page 15: ...25mm x 25mm x 1mm tube SHS and can be supplied as brackets only for customising the length of the drop on site or supplied as a complete kit with brackets pre cut poles and connections The standard le...

Page 16: ...rd on position is at full power and temperature The controller has 3 settings they are High Medium and Low The controller allows a combination of the multiple timer 1 2 4 hour and heat outputs High Me...

Page 17: ...supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Do not allow any cables...

Page 18: ...here including cigarette smoke pollution etc will tarnish the surface of the heater In this case additional cleaning and maintenance may be required The cleaning process at least every three months wi...

Page 19: ...connected to a wall switch If it does not please contact a licensed electrician to arrange installation of the socket outlet wall switch and isolation switch It is recommended to use SKU 200064 not in...

Page 20: ...the product to the Lucci factory or any other location authorised in writing by Lucci is the sole responsibility of the customer All products are inspected and tested before despatch and are at the ri...

Page 21: ...warranty requests for repairs or replacements must be accompanied by a complete Warranty Claim Form available from Lucci together with proof of purchase and where possible photos of the installation a...

Page 22: ...ils below and keep this installation manual for future reference You will need to provide proof of purchase and installation by a licensed electrician Customer Name Address Phone No Product Model No P...

Reviews: