![Lucci Fresco THERMASTRIP 200060 Installation Instructions Manual Download Page 7](http://html1.mh-extra.com/html/lucci-fresco/thermastrip-200060/thermastrip-200060_installation-instructions-manual_1945888007.webp)
Installation Instructions
7|
P a g e
v 1 . 0
Radiant Footprint
THERMASTRIP electric heaters produce radiant heat which
heats objects rather than the air. Therefore, it is imperative that
objects to be heated (ie. people), are within the direct radiant
footprint of the heater. The diagram to the right shows the radiant
footprint of THERMASTRIP and is an approximate guide based
on a fully enclosed, outdoor environment. This diagram shows
that the maximum heat output is found directly under the heater,
and the temperature decreases as you move away from the
heater. It highlights the importance of maintaining recommended
mounting heights, and if possible, positioning the heater directly
above the area to be heated. Also, the temperature (ie. surface
temperature) is the same for all 4 models, regardless of the
wattage. However, as the size increases and the length of the unit
increases, the radiant footprint will be larger.
The below diagrams show the approximate heating area for each model, based on both an indoor and outdoor enclosed environment,
with direct overhead mounting. Radiant footprint is reduced in angled, wall mounted applications.