User Manual of Digital Video Recorder
162
10.9
Configuring HDD Error Alarms
Purpose:
You can configure the HDD error alarms when the HDD status is
Uninitialized
or
Abnormal
.
Steps:
1.
Enter the Exception interface.
Menu > Configuration > Exceptions
2.
Select the Exception Type to
HDD Error
from the dropdown list.
3.
Check the checkbox(s) below to select the linkage action(s) for HDD error, as shown in Figure 10. 25.
The linkage actions can be selected to: Audible Warning, Notify Surveillance Center, Send Email and
Trigger Alarm Output.
Note:
Trigger alarm output is applicable to the ST series.
Please refer to
Chapter 8.7 Setting Alarm Response Actions.
Figure 10. 25
Configure HDD Error Alarm
4.
When the Trigger Alarm Output is selected, you can also select the alarm output to be triggered from the list
below.
5.
Click the
Apply
button to save the settings.
©2015 LT Security, Inc. All Rights Reserved. White papers, data sheets, quick start guides, and/or user manuals
are for reference only and may or may not be entirely up to date or accurate based upon the version or models.