Chapter 5. Application instructions
5-109
-
In the following cases, operation error occurs;
a) The slot number specified as ‘sl’ is not a special function module
b) The value of ‘n2’ is over 512, or [ D+n2 ] is exceeds the specified device range.
-
Execution conditions
2) Program example
-
Program that reads 4 words from the address 0 of buffer memory of A/D module, and stores them
to the 4 words from D0010 of CPU module.
Input condition
GET
GETP
Executed only once
Executed only once
Executed per scan
Executed per scan
Power
supply
module
CPU
module
16 points
input
module
32 points
input
module
4
channel
A/D
module
2
channel
D/A
module
slot 0
slot 1
slot 2
slot 3
GET h0002 h0000 D0010 h0004
h0F0F
hE246
h1122
h4477
[ 0 ]
4 words
The buffer memory of
the A/D module
h4477
h0F0F
h1122
D0010
4 words
CPU module
hE246