Chapter 5. Application instructions
5-84
-
Execution conditions
2) Program example
-
Program that transfer the content of the M03+n word to M01 word when P020 is switched on. The n
is stored at D0010 word.
Input condition
FILR, DFILR
FILRP, DFILRP
Executed only once
Executed only once
Executed per scan
Executed per scan
FILRP M03 M01 D0010
P020
h5030
h6030
M002
M000
M001
when n=3
M003
M004
M005
M006
M007
h6030
h5030
h6030
M002
M000
M001
when n=4
M003
M004
M005
M006
M007
h5030