LSI LASTEM M-Log – User’s manual
46
parameters, and it’s called
automatic transmission rate
. In this mode M-Log results like LSI CISS
multi-channel sensor and so its measurements can be received by an other M-Log.
In addition to the CISS protocol, M-Log is able to manage, through serial port 2, other protocols:
TTY (see §5.6.4);
Modbus (see §5.6.5) ;
Gill anemometer;
Giletta GIL-D-I Ice sensor (only if it’s required);
Aeroqual gas analyser;
Hydrolab;
Lufft UMB sensor (only if it’s required);
Climatronics sensor.
A GSM or GPRS telephonic modem can be connected to serial port; in this case, if you want reduce
the energy consumption of modem, it’s possible follow the instruction of §5.7. Anyway, if removed
appropriately, the use of a modem doesn’t block the local communications with M-Log, connecting
PC to serial port of instrument directly.
Note
: in case PC has to execute any communication with the instrument through serial port, and the
latter has been programmed for spontaneous transmission of data at frequent rate (intervals shorter
than 10 s), PC could meet some difficulties to start first communication; so it could be necessary to
start operation several times. After the reception of message, M-Log deactivates spontaneous
communication for 1 minute, in order to make further communications with PC easier.
M-Log manages the flow check according to two choices (none, only RTS) that can be selected
through configuration from 3DOM (see §4.4.4.3 of manual SWUM_00339 inside CD of LSI
LASTEM – MW6501 products).
Protocol / Device
Function
Com1 Com2
(Owner) LSI
LASTEM CISS
Transmission of instantaneous values of the measures (in polling
mode or spontaneous transmission)
X
X
Transmission and reset of elaborated data from memory
X
X
Transmission of instrument registry information
X
X
Transmission and setting of configuration parameters (measures,
elaborations, communication, actuation logics, etc.)
X
X
Transmission and reset of diagnostic information updated in real
time or stored in memory (system log)
X
X
Transmission of actuation logics state (allarms) or digital outputs
state (actuators) (*)
X
X
Transmission and setting of system date/time
X
X
Setting of digital outputs (actuators)
X
X
Acquisition of instantaneous values sampled from sensors with LSI
LASTEM CISS protocol
X
X
Management of system commands (start/stop survey, memory
format, instrument reset, etc.)
X
X
TTY
Transmission of instantaneous values of the measures (in polling
mode or spontaneous transmission)
X
Transmission of instrument registry information
X
Transmission and reset of diagnostic information updated in real
time
X
Setting of system date/time
X
Modbus RTU
Transmission of instantaneous values of the measures (fixed point or
X