Gen VI Dimmer
User Manual
Page 7
1.2.2
GEN·VI Control Philosophy
Each channel can be independently set to dim mode (with a selection of standard dimming curves
in either 8-bit or 16-bit accuracy) or relay mode (TruPower) for direct power switching.
The control source for each channel can be either,
DMX Only
. Channels
configured for “DMX Only” are controlled by the DMX slot to which they
have been patched. If the DMX signal fails, the channels can either hold their last state or
after a programmable delay time, fade
to a “DMX Loss Memory” previously stored in the
GEN·VI.
Every DMX controlled channel can be set to be either a dimmer or a
“Trupower” switch. When
set to Trupower,
•
The channel will switch ON when the DMX signal exceeds 60%.
•
The channel will switch OFF when the DMX signal drops below 40%
Auto Power
. C
hannels configured for “Auto Power” are switched on when the lighting
console is turned on and a valid DMX signal is detected on the input to the GEN·VI,
regardless of actual DMX levels. Therefore, the lighting, audio and video equipment
connected to these channels will be powered up without user intervention. When the console
is turned off, the equipment will
remain on for a programmable “hold time” and then be
automatically switched off. This means there is less chance of some equipment being
accidentally left on when not in use, ensuring the maximum service life and a lower power
bill.
Global control of “Auto Power” can be enabled/disabled.
See section 2
“Quick Start Guide” for details on how to change channel modes.
Channels can also be controlled from the touch screen by selecting
Riggers Control
. See section