Gen VI Dimmer
User Manual
Page 22
“TruPower” is used for devices that do not fade, but need to be switched OFF or ON such as motors,
discharge lamps and some LED fixtures.
•
When the control signal exceeds 60% the Trupower channel will switch ON.
•
When the control signal drops below 40%, the Trupower channel will switch OFF.
Selecting
Config
,
Dim/TruPower
provides a rapid means of for configuring channels as either
“Dimming” or “TruPower”.
Press a channel to toggle its mode
between “Dimmer” mode and “TruPower” mode. A light grey
button indicates dimmer mode and a dark grey button indicates TruPower mode. Configure your
channels then press
Save
.
Note: Changing a channel from TruPower to Dimming mode can potentially damage connected
equipment that should not be connected to a dimmed output. If you change a channel from TruPower
to Dimming you will be asked to
Confirm
your changes.
If you change a channel from Dimming to TruPower, no confirmation is required and the changes
will be applied when you press
Save
.
Note:
that channels can also be changed between Dimming and TruPower in the “Channels” menu
with more options available. See section 5.10
5.8
DMX Menu
Selecting
Config
,
DMX
provides menus for,
•
Patching DMX.
•
Editing and activating the DMX Loss (D) memory.
•
Enabling and time setting the Auto Power function.
•
Viewing the Input DMX signal.
Dimmer mode.
Light grey
TruPower mode.
Dark grey