Gen VI Dimmer
User Manual
Page 34
5.12.1
Code (Software) Upgrade
LSC Control Systems has a corporate policy of continuous improvement to its products. The GEN·VI
dimmer software (firmware) is subject to this policy as new features are added and existing features
improved. The software version of your GEN·VI
dimmer
can be checked from the “Dimmer Output”
home page by pressing
Status
,
About
.
To upgrade your GEN·VI software, download the latest version from the LSC web site.
As of 2021, GEN·VI units are manufactured using two possible types of controller module. Both
types perform the same functions but require their own version of the operating software. The
downloaded software is a ZIP file containing both versions. Double click on the ZIP file to
automatically extract the two files then save both files to a SD card. The controller module in the
GEN·VI knows which filename to look for so only the correct code will be loaded and upgraded.
Insert the SD card containing both files into the SD card socket on the GEN·VI. Press
Config
,
System
,
Code Upgrade
.
5.12.2
Reset
The GEN·VI provides two different types of reset function. Press
Config
,
System
,
Reset.
There are
two options:
5.12.2.1
Restart
In the unlikely event that the GEN·VI fails to respond, the operating system may be restarted so that
the software may initialise and recommence normal operation. Performing a restart will not affect
any of the settings or memory.
5.12.2.2
Reset To Defaults
This will ERASE all memory from the GEN·VI (except the owner name and logo) and reset to
defaults.
The default settings are;
ATTRIBUTE
DEFAULT SETTING
Min Level
0%
Max Level
100%
Fade Curve
Linear Curve
Control Source DMX Only
Patch
1:1 starting at DMX slot 1
5.12.3
Fan Control
The internal fan in the GEN·VI is used to control its temperature. To set the fan control press
Config
,
System
,
Fan Control
.