Chapter 8 Table of Functions
8-38
No. Comm. No. Function
Display
Name
Setting Range
Initial
Value
Shift in
Operation
Control Mode
V/F
SL
VC
SLT
VC
T
26 0h1B1A UL Warn Time light load alarm time
0 ~ 600.0 [s]
10.0 O
O
O
O
O
O
27 0h1B1B UL Trip Sel light load failure selection
0 None
0:None O
O
O
O
O
O
1 Free-Run
2 Dec
28 0h1B1C UL Trip Time light load failure time
0 ~ 600 [s]
30.0 O
O
O
O
O
O
29 0h1B1D UL LF Level light load lower limit level
10 ~ 30 [%]
30 O
O
O
O
O
O
30 0h1B1E UL BF Level light load upper limit level
30 ~ 100 [%]
30 O
O
O
O
O
O
31 0h1B1F No Motor Trip movement in case of no motor
detection
0 None
0: None O
O
O
O
O
O
1 Free-Run
32 0h1B20 No Motor Level no motor
detection current level
1 ~ 100 [%]
5 O
O
O
O
O
O
33 0h1B21 No Motor Time no motor
detection delay
0.1 ~ 10.0 [s]
3.0 O
O
O
O
O
O
34 0h1B22 Thermal-T Sel
movement selection after motor
overheat detection sensor
detection
0 None
0 : None O
O
O
O
O
O
1 Free-Run
2 Dec
35 0h1B23 Thermal In
Src
motor overheat
detection sensor
input selection
0 None
0 : None
X
O
O
O
O
O
1 V1
2 I1
3 V2
4 I2
36 0h1B24 Thermal-T Lev motor overheat detection
sensor failure level
0 ~ 100 [%]
50.0 O
-
-
-
-
-
37 0h1B25 Thermal-T Area motor overheat detection
sensor failure area
0 Low
0 : Low O
O
O
O
O
O
1 High
40 0h1B28 ETH Trip Sel electric thermal failure
selection
0 None
0 : None O
O
O
O
O
O
1 Free-Run
2 Dec
41 0h1B29 Motor Cooling motor
cooling fan type
0 Self-cool
0:Self-
cool O
O
O
O
O
O
1 Forced-cool
42 0h1B2A ETH 1min electric thermal 1 minute rating 120 ~ 200 [%]
150 O
O
O
O
O
O
43 0h1B2B ETH Cont electric thermal consecutive
rating
50 ~ 200 [%]
120 O
O
O
O
O
O
45 0h1B2D BX Mode BX mode select
0 [sec] Free-
run 0.0 (Free-
run) O
O O O X X
0.1~600.0
[sec] Dec
50 0h1B32 Stall Prevent stall preventing movement
Bit 0000 ~ 1111
0000
X
O O X
O
X
1 Accelerating
2 Steady speed
3 Decelerating
4 Flux Braking