L7C Series AC Servo Drives Quick Start Guide
Page 60 of 60
L7C Servo Drives Quick Start Guide – 1st Ed. Rev A, 11/29/2021
Step 12: Set Analog Torque Command Clamp Level
Tor
que Mode S
tep 12
Substep
Task
A
Go to the
Object Dictionary
in the Drive CM software
B
Find
Analog Torque Command Clamp Level
(Object 0x2212) This parameter is the same as a
deadband
C
Enter a value to avoid undesired motion as a result of signal noise The value entered here will
cause the shaft speed to remain at 0 RPMs until the analog voltage is above a set mV value
D
Torque Mode Commissioning is now complete