12 

HANDLING OF FIXTURE 

 

    

 

Heavy lift, minimum two persons, the weight is approximately 156 pounds.  

 

Hanging of the fixture creates a number of potential pinch points.  

 

Use fixture lifting handles provided as well as the yoke tubes. 

 

If there are any concerns regarding handling please contact your 

supervisor. 

 

Ensure hanger bolts are installed immediately after hanging, before the 
ratchet straps are tensioned.  

 

Ratchet straps must have a minimum of one and a half wraps around the 

ratchet drum at all times. 

 

Removal of shipping case covers require two persons to lift. Always use 

lifting points to avoid potential pinch points. 

 

 

Fixture lifting points 

Fixture approximately  

156 pounds 

Summary of Contents for single

Page 1: ...LRX SINGLE Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 1 1 ...

Page 2: ...ble of supporting the total weight of the load In case of malfunction disconnect all power supplies discontinue use notify supplier Area under fixture must be cordoned off at all times and kept clear of all personnel Prior to operation a daily inspection and log are required For handling information see page twelve Do not operate without lens in place If using a power trolley with this fixture ple...

Page 3: ...meets all local codes prior to operation Safety power lockout procedures must be followed Safe electrical and working practices must be observed WARNING This fixture has rotating parts with pinch points Fixture may move without warning No personal within range of motion Never operate with any covers missing Fixture has fans which start automatically without warning WARNING High energy light output...

Page 4: ...r to the fixture with the power off Damage could result if attempting to connect the hand controller to the LRX fixture while the power is on The mode square icon on the left is used to toggle between DMX mode and FIXTURE mode FIXTURE mode is designated by a capital F in the left most digit with the remaining two digits indicating the fixture number E g F01 fixture 1 etc DMX mode is shown as a thr...

Page 5: ...errupt Pressing and holding the mode button will provide access to the hour meter Once in hour meter mode press the up icon to display bulb hours indicated as a scrolling number It will show as a blank digit followed by three digits then a decimal place and two more digits i e _120 59 The bulb hours can be reset by pressing and holding the store button until the meter zeros about five seconds To d...

Page 6: ...11 lamp control unimplemented N 12 motor control MODE N 12 127 BUMP MODE N 12 127 FADER MODE N 13 reserved future use N 14 reserved future use N 15 reserved future use If MODE BUMP n 12 128 N 0 127 pan left N 1 127 pan right N 2 127 tilt up N 3 127 tilt down N 4 127 spot N 5 127 flood N 6 127 trolley left N 7 127 trolley right N 8 9 reserved future use If MODE FADER n 12 128 N 0 64 pan left N 0 12...

Page 7: ...control of tilt up down pan left right and flood spot functions and will also shut off individual gel cooling fans or all gel cooling fans connected to that controller All switches act as momentary type When the Individual Gel Fan Stop switch is held the gel fan for the fixture indicated on the display stops When the All Gel Fans Stop switch is held all gel fans connected to that hand controller w...

Page 8: ...approx 12KWSE Volts 120 240 VAC 100 50 amps approx Head Input Connector Input is configured to accept Arri 12 18K connector LRX fixture connector Cannon part CB0 28A16PS A232 Tungsten mode requires an input connector with tails that mate to local distribution a Pin C Line b Pin H Neutral c Pin B Ground Or see wiring diagram for pin connections Physical Tilt from horizontal 20 degrees to negative t...

Page 9: ...LRX SINGLE Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9 9 ...

Page 10: ... placed in the inside slot and the outside slot The heat shield in the outside slot helps to maintain the column of cool air created by the filter fans If a color correction filter and a diffusion filter are both required the color filter should be placed in the outside slot the diffusion filter placed in the center slot and heat shield in the inside slot This provides the longest filter life It h...

Page 11: ...LRX SINGLE Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 11 Roscoe Heat Shield Roscoe Heat Shield Color or diffusion filter ...

Page 12: ...lifting handles provided as well as the yoke tubes If there are any concerns regarding handling please contact your supervisor Ensure hanger bolts are installed immediately after hanging before the ratchet straps are tensioned Ratchet straps must have a minimum of one and a half wraps around the ratchet drum at all times Removal of shipping case covers require two persons to lift Always use liftin...

Page 13: ...LRX SINGLE Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 13 13 Ensure 1 5 wraps on ratchet drum Hanger Bolt ...

Page 14: ...y See illustration below Gel frame holder damage could result if forced into position in shipping case Align hanger so that the fixture is pointed straight ahead The fixture should be left in spot position with the socket tightened slightly to prevent the t handle from turning out during shipping Install onto shipping frame tighten T bolts and ratchet straps and ensure there is a minimum of 1 5 wr...

Page 15: ...t produces a more stable arc Lamps should be wiped with 99 alcohol and clean paper towels or lint free cloth after installation Clean close and lock the lens Close and secure the lamp lock door Heat shield must always be used in front of the lamp This provides protection for the lens from rain and also helps to contain the glass fragments in event of lamp breakage Ensure power supply matches lamp ...

Page 16: ...at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 16 16 IMPORTANT When LRX extended 6KSE lamps are not available a socket extender will be required to compensate for the shorter A C L of the standard 6KSE lamp Part number G38 6X ...

Page 17: ... of 1 5 wraps on the ratchet to ensure they remain tight Always use approved safety cables secured to a point capable of supporting the total weight of the load All power and data cables must have a strain relief attached When fixtures are mounted in close proximity to each other care must be taken so that output energy from one fixture is not directed at another fixture or electrical cabling If c...

Page 18: ...PECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 18 18 Load must be centered front to back as well as side to side Using two truss plates 1 2 X 3 per side a minimum of two structural members must be captured Fasten using X 4 bolts with washers lock washers and nuts four places ...

Page 19: ...ires and pins are required to operate hand controller Check hanger display for proper addressing and mode For use with hand controller the fixture display must show the F prefix not the three digit DMX channel and the display must not be flashing It is important to note that the LRX fixture will not begin responding to a newly selected FIXTURE DMX address until it has been stored by pressing and h...

Page 20: ...icking sound once each revolution when driven by the motor if the clutch has exceeded it preset limits If any of these conditions exist suspend use of the product and call for service There are no user serviceable parts LAMPS NOT WORKING TUNGSTEN MODE LAMP NOT WORKING Fixture must have 120VAC at the control input u ground plug not a dimmed line and display at the rear of the hanger assembly must b...

Page 21: ...s above 205 VAC when under load Check socket contacts and wiring to socket Check for signs of overheating contacts or arcing Wet ballasts will need to be placed in a warm dry location and allowed to dry before attempting to use Hot restrike it is important to note that if the power to the U ground plug is interrupted the lamp will shut off and will require a fifteen minute cooling cycle Power shou...