LRX SINGLE
Check on line for the latest updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
6
6
DMX CHANNEL ALLOCATION
When using the LRX with a lighting console or other device that offers
discrete control over the DMX channels, they are used by the fixture as follows:
Where N= base channel of fixture. [LRX DMX address shown on display]:
N + (0-9) = motor control (depends on MODE)
N+10 = GEL fan ON/OFF (OFF<127<=ON)
N+11 = lamp control (unimplemented)
N+12 = motor control MODE: N+12<127 = BUMP MODE
N+12>=127 = FADER MODE
N+13 = reserved (future use)
N+14 = reserved (future use)
N+15 = reserved (future use)
If (MODE = BUMP): (n+12<128)
(N+0 > 127) = pan left
(N+1 > 127) = pan right
(N+2 > 127) = tilt up
(N+3 > 127) = tilt down
(N+4 > 127) = spot
(N+5 > 127) = flood
(N+6 > 127) = trolley left
(N+7 > 127) = trolley right
(N + 8, 9) = reserved (future use)
If (MODE=FADER): (n+12>=128)
(N+0 < 64) = pan left
(N+0 > 127) = pan right
(N+1 < 64) = tilt up
(N+1 > 127) = tilt down
(N+2 < 64) = spot
(N+2 > 127) = flood
(N+3 < 64) = trolley left
(N+3 > 127) = trolley right
(N+4 thru 9) = reserved (future use); each motor above is stopped
when the fader is in the middle of its range (DMX value 64-127)