background image

1

BEAM 380W

TV-N380BEAM

User manual

Please read this instruction carefully

Summary of Contents for TV-N380BEAM

Page 1: ...1 BEAM 380W TV N380BEAM User manual Please read this instruction carefully ...

Page 2: ...iption 7 3 1 Control Panel 7 4 lamp 8 4 1 lamp bulb 8 5 Fixture settings 8 5 1 Main Function 8 5 2 Error message 11 6 Universal DMX controller control 12 6 1 Connection 12 6 2 Channel settings 13 6 3 Address code setting 13 6 4 DMX 512 channel 13 7 Fault Handling 18 8 Maintenance and cleaning 19 ...

Page 3: ...t must be installed in a well ventilated place at least 50 cm away from the adjacent surface Make sure the ventilation holes are clear to avoid overheating when the fixture is running Before operation make sure that the power supply voltage matches the power supply voltage required by the fixture Please ground the conductor to prevent electric shock Ambient temperature Do not operate the fixture b...

Page 4: ...or maintenance When shipping again please use the original packaging material To avoid fire or electric shock do not expose the fixture to rain or wet areas There is a danger of explosion due to high temperature bulbs Please do not turn on the lamp within 15 minutes after power off Please replace the bulb in time if the bulb is damaged deformed by heat or exceeds the service life Do not stare at t...

Page 5: ...ical locking function to prevent damage to lamp during transportation Dimming strobe 0 100 smooth dimming multiple speed strobe effect Color wheel Color wheel 2 color wheel each has 11 color white Two way rainbow effect Fixed Gobo Wheel Gobo Wheel 1 fixed gobo wheel 14 gobo white Magnetic positioning function for easy initial Prism Prism1 48 prisms that can be rotated and overlapped in two way Pri...

Page 6: ... linear focusing Heat dissipation Fan cooling General controller DMX 512 controller DMX signal input output 3 pin XLR signal line interface N W 22 4Kg G W Carton 26 5Kg Dimension 618 422 301mm Product Illumination Chart ...

Page 7: ... function Confirm selected function 3 Phoenix Plug For DMX transfer 4 Fuse T 8A Overcurrent protection 5 DMX Input For DMX 512 connection use 3 pin XLR signal cable to connect the fixture and DMX console and input DMX signal 6 DMX Output Used for DMX 512 connection use 3 core XLR signal cable to connect to the next machine 7 Power Switch Turn the power on or off 8 Power Cable Connect to power supp...

Page 8: ...unreasonable operation and other factors Therefore please do not use bulbs that exceed the service life 4 Make sure the bulb is installed in the center to ensure the best results 5 Fixture settings 4 1 5 1 Main Function Turn on the machine press the ENTER button to enter the menu mode use the UP and DOWN buttons to find the menu when the preset menu is displayed on the display press the ENTER butt...

Page 9: ...ically reverse Yes No The display is always bright Yes No Default delay off Horizontal angle 180 360 540 Factory default 540 Vertical angle 90 180 270 Factory default 270 Wireless link Yes No Voice Chinese English Factory default Chinese Error message Yes No Factory settings Operating mode Select channel mode Full mode 24 CH Yes No Factory default Full mode 18 CH Yes No Lite mode 15 CH Yes No View...

Page 10: ...t in program1 Yes No Yes No Built in program9 Yes No System message Device version number Equipment temperature Fan speed Error detection Equipment running time Lamp time Lamp control Bright light bulb Yes No Turn on the electric light bulb Yes No Console control light bulb Yes No Turn on lamp delay 0 535 Half power delay 0 535 Reset lamp time Yes No Lamp maintenance internal use 0 255 Remaining m...

Page 11: ...11 service Equipment maintenance times Equipment fine tuning calibration Device data clear Equipment usage records ...

Page 12: ...ton to exit 5 2 Error message Temperature error The temperature detection board may be damaged Fan error The fan and its control parts may be broken Magnetosensitive error For the magnetic sensitive function part may be broken Optocoupler error Optocoupler and its control part may be broken The above situation may occur when the Fixture is turned on or reset some parts may be damaged Please contac...

Page 13: ...rallel DMX512 signal transmission speed is very fast Damaged signal wires weak soldering poor contact etc willaffectsignaltransmissionandcausethesystemtoshutdown 3 When the machine power supply of a unit is disconnected the connection of DMX output and input is bypassed in order to maintain the connection of the DMX line 4 Each lamp must have an address code which can receive the information sent ...

Page 14: ...isplay then use the UP DOWN button to select the address code 1 512 press the ENTER button to save Press the MENU button to return to the previous menu or wait 30 seconds and automatically exit the menu mode Please refer to the following chart to set the address codes of the first 4 fixtures Channel mode Fixture 1 address code Fixture 2 address code Fixture 3 address code Fixture 4 address code Fu...

Page 15: ...st 168 203 Slow to close and fast to open from slow to fast 204 239 Pulse strobe from slow to fast 240 247 Random strobe from slow to fast 248 255 Open 9 9 Color wheel 1 0 4 White light 5 9 Deep red 10 14 Blue 15 19 Green 20 24 Orange 25 29 Magenta 30 34 Yellow 35 39 Cyan 40 44 Red 45 49 Navy blue 50 54 Dark green 55 59 Yellow green 60 61 White light 62 159 Color position half color 160 219 Positi...

Page 16: ...erse rainbow from slow to fast 11 11 8 Gobo 0 3 White light 4 7 Gobo1 8 11 Gobo2 12 15 Gobo3 16 19 Gobo4 20 23 Gobo5 24 27 Gobo6 28 31 Gobo7 32 35 Gobo8 36 39 Gobo9 40 43 Gobo10 44 47 Gobo11 48 51 Gobo12 52 55 Gobo13 56 59 Gobo14 60 63 Gobo14 dithering effect from slow to fast 64 67 Gobo13dithering effect from slow to fast 68 71 Gobo12dithering effect from slow to fast 72 75 Gobo11dithering effect...

Page 17: ...17 to fast 88 91 Gobo7dithering effect from slow to fast 92 95 Gobo6dithering effect from slow to fast 96 99 Gobo5dithering effect from slow to fast 100 103 Gobo4dithering effect from slow to fast ...

Page 18: ...mb prisms 15 Prism 2 rotation 0 127 Three rows of 48 honeycomb prism rotation positions 128 189 Forward rotation from fast to slow 190 193 Stop 194 255 Reverse rotation from slow to fast 16 Prism3 0 255 24 honeycomb prism 17 Prism3 rotation 0 127 24 honeycomb prism rotation position 128 189 Forward rotation from fast to slow Stop Stop 194 255 Reverse rotation from slow to fast 18 Prism4 0 255 4 ro...

Page 19: ... Prism Wheel 2 Effect 1 128 255 Prism Wheel 2 Effect 2 15 12 Prism wheel 2 rotation 0 127 Prism rotation position 128 189 Forward rotation from fast to slow 190 193 Stop 194 255 Reverse rotation from slow to fast 22 16 13 Focusing 0 255 Focusing focal length 23 17 14 Fog 0 15 No function 16 255 Fog 24 18 15 Functional channel 0 129 No function 130 139 Turn on the bulb 140 149 XY Reset 150 159 Colo...

Page 20: ...d 2 Check whether the address code setting is correct 3 If the DMX signal transmission is intermittent check whether the connection between the XLR seat and the signal cable is good 4 Try it with another controller 5 Check if the distance between the DMX signal wire and the high voltage wire is too close which will damage or interfere with the signal circuit C Channel fails 1 1 Stepper motor or mo...

Page 21: ... Clean The inside and outside of the lens and the mirror must be wiped frequently so that the lighting effect is better The wiping frequency depends on the environment The damp smoky and particularly dirty environment is prone to dusting the lens Use soft linen and special glass scrubbing agent Dry parts carefully Wipe the outside of the lens at least once every 20 days Wipe the inside at least ev...