LRX SINGLE
Check on line for the latest updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
8
8
FIXTURE SPECIFCATIONS
Electrical:
Control power: Volts – 120 AC – non-dimmed feed line.
Hertz – 50 - 60
Amps – 2.0
U- Ground plug
Metal Halide Lamps:
6KWSE: 125VAC / 48 amps approximate
12KWSE: 160 VAC / 75 amps approximate
18KWSE– 225 VAC / 85 amps approximate
Tungsten Lamps: 10KWSE Volts: 120/240 VAC - 83/41.5 amps approx.
12KWSE Volts: 120/240 VAC - 100/50 amps approx.
Head Input Connector:
Input is configured to accept Arri 12/18K connector.
LRX fixture connector: Cannon part# CB0-28A16PS-A232
Tungsten mode requires an input connector with tails that mate to local
distribution.
a.
Pin “C” = Line
b.
Pin “H” = Neutral
c.
Pin “B” = Ground
Or see wiring diagram for pin connections.
Physical
Tilt from horizontal: +20 degrees to negative two hundred & twenty-five
degrees
Pan - 340 degrees
Weight - 156 pounds
Designed to accept gel frames: 30” X 30”
Fixture mounting hooks have been designed to mate with truss chords
not greater than two inches (50.8mm) in diameter