- Instruction Manual for ESS R050096 -
42
needs to be charged
for a period of time
before it is allowed to
discharge
Battery over
temperature
Allow to stand at room temperature
for more than 3 hours
Battery over temperature
Allow to stand at
room temperature for
more than 3 hours
Battery over temperature
Red light failure prompt
Others
According to the prompted fault
information, check the indicator
function status table to find the
corresponding fault reason;
The inverter is powered on by
the battery for the first time,
the battery reports discharge
short circuit protection
Inverter battery side
input terminal parallel
capacitance value is
larger
Battery protection can be restored
automatically
The inverter cannot start
Battery voltage is too
low or SOC is lower
than shutdown
protection value
After starting the inverter through the
grid, charge the battery
The battery cannot be charged
through the grid
No "Grid Allowed
Charging" is selected
in the Battery Setting
interface or "Grid
Charging Allowed" is
not selected in the
Time of Use setting
interface
1. Check whether the Battery Setting
Grid Charge in the LCD screen is
enabled
2. Check whether the Grid Charge of
the Time of Use of System Work Mode
in the LCD screen is enabled
Battery fault
protection
According to the prompted fault
information, check the indicator
function status table to find the
corresponding fault reason;
Abnormal power grid
Check whether the grid voltage is
normal