background image

 

 

34

6.3.3. Filter cleaning 

Note 

The used filters and the liquids used for washing are special waste. Take this waste to 

authorised collection and disposal 

centres

 
It is advisable to regularly replace the synthetic filters as indicated in the Programmed Maintenance Table (item 

6.3.1

). If the 

filters structure is fully integral, it is possible to regenerate them (instead of replacing them) by putting them into a solution of 
industrial detergent and water for about 12 hours. Before re-assembling the filters, dry them with a jet of compressed air or 
leave them to dry naturally. 
 

Danger! 

The used filters and the seals are special waste. While waiting for disposal, they must be kept in hermetically 
closed containers, which must be located far from the working areas. 

 

6.3.4. Internal cleaning 

 
Careful and regular cleaning of all the internal parts (shell, drainage pipe, drainage ring, etc.) ensures high performance and 
long life of the air filter. 

It is of fundamental importance to periodically check the inside of the centrifuge or the blades of the turbine to 
eliminate eventual deposits of metal particles, sludge or other material which could cause loss of balance of the 
centrifuge or of the turbine. 

 

Warning 

The functioning of the air filter with unbalanced turbine or centrifuge (even if for a short time) could seriously 
damage the air filter components. 
 

For the internal cleaning of the air filter and the rotors (either turbine or centrifuge) use a clean brush saturated in a mild 
industrial detergent solution. Alternatively standard liquid soaps can be used.  
Should the dirt be very resistant, it is advisable to remove the rotor (for rotor dismantling see 6.4) and use the following 
alternative cleaning solutions: 

 

-

 

A jet of steam at a temperature of over 100

°

 C. 

-

 

An industrial detergent solution in water, soaking the rotor for at least 12 hours. 

 
Allow the centrifugal device to dry in the open air or dry with a jet of compressed air. 

 

6.4. Special maintenance 

Danger! 
The special maintenance operations are to be undertaken by qualified technicians only. Skilled electricians should 
carry out work on the electrical parts. 
 

Before beginning the maintenance procedure: 

  Position the general switch of the machine tool to 

"OFF"

 and lock it. 

  Wait at least 3 minutes in order to allow the rotor to come to a complete stop. 

  Disconnect the control device from the plug and socket of the air filter. 

  Place on the machine tool the apposite sign 

"Maintenance in progress"

.

 

  Wear goggles and protective clothing (gloves, safety shoes, etc.). 

6.4.1. General disassembly and reassembly 

 

Warning! Danger! 

During the re-assembly and before starting up the air filter again make sure that all the components are correctly 
secured and mounted. 
In particular, check: 

 

The correct tightening of the screws connecting the motor to the relative support.  

 

The correct tightening of the screw connecting the rotor to the motor shaft. 

EN

Summary of Contents for Darwin 1200 D

Page 1: ...Manuale d istruzioni Instructions manual Manuel d instructions Handbuch Manual d istrucciones Mod 600 1200 2000 3000 EN IT FR DE ES...

Page 2: ...HARACTERISTICS 24 3 HANDLING AND STORAGE 24 3 1 HANDLING OF PACKED UNITS 24 3 2 STORAGE 24 4 INSTALLATION 24 4 1 MINIMUM SPACES FOR INSTALLATION 25 4 2 CONDITIONS AND OPERATIONAL LIMITS 25 4 3 INSTALL...

Page 3: ...that the Supplier deems suitable in order to ascertain the effective non conformity or defect of the product The lack of communication of the potential non conformity or fault of the product in the t...

Page 4: ...he supplier 1 3 General delivery notes The air filters are packed in carton boxes provided with handles Upon receipt of the unit open the box and check that The air filter is not damaged The goods cor...

Page 5: ...the machine switch board to OFF and fasten it with a padlock Disconnect the control device from the plug and socket of the air filter Wait at least 3 minutes in order to allow the air filter rotor to...

Page 6: ...unction and field of application The air filter DARWIN D double centrifuge is suitable for all machine tools for metal production other than grinders and sharpeners It specifically eliminates neat or...

Page 7: ...xcept Darwin 3000 A fork lift The EUR pallet with several boxes is to be transported by A forklift of adequate capacity for the load to be handled Cranes bridge cranes or other lifting means of adequa...

Page 8: ...ir filters of the Darwin range the physical characteristics of the air to be purified should preferably respond to the following characteristics Temperature between 5 C and 40 C Relative humidity from...

Page 9: ...eas with a considerable presence of solid dust and sprays of coolant liquids To avoid pressure drop it is advisable to use a suction pipe with a maximum length of 2 metres Furthermore to prevent liqui...

Page 10: ...radle and moved on holes prepared in the underlying transverse beam except for the Darwin 600 in which there is only one transverse beam In this position the aspirator can only be used in a horizontal...

Page 11: ...Vertical installation Installation in horizontal position drawing 9 Insert the pipe TFM on the connection plate PRT and secure it using a hose clamp In alternative the pipe can be inserted directly i...

Page 12: ...3000 with 60 Hz motor the protection is a a thermal switch for 3 12 A with cycle time 20 seconds b a magnetic switch for 8 A running current Check that the connection voltage indicated on the test she...

Page 13: ...top the Darwin only during the halts between work shifts with the machine tool at a standstill 6 Maintenance Warning Danger Respect carefully the programmed maintenance timetable illustrated in the pr...

Page 14: ...necessary to undertake a preventive programmed maintenance at regular intervals The programmed and preventive maintenance operations consist in the periodic cleaning or substitution of filters seals...

Page 15: ...SE filters can be cleaned rather than replaced at the above mentioned intervals provided that their structure is fully integral In case of installation of the machine in smaller areas maintenance is r...

Page 16: ...Replace seals GSM and GTI if necessary Clean or replace the FPS for D 3000 FPSE and FPSI filter see 6 3 3 Insert the FPS for D 3000 insert FPSI the net and FPSE filter on the net of the rear lid Reas...

Page 17: ...mponents For the internal cleaning of the air filter and the rotors either turbine or centrifuge use a clean brush saturated in a mild industrial detergent solution Alternatively standard liquid soaps...

Page 18: ...other components of the air filter it is advisable to regularly check that the motor shaft rotates freely and does not produce anomalous sounds Anomalous noises coming from the electric motor are usua...

Page 19: ...rations The used filters the internal parts in rubber and all components with oil residuals are special waste to be disposed through authorized organizations To allow for the reutilization of the raw...

Page 20: ...OTOR SUPPORT KIT KIT SUPPORT MOTEUR BEFESTIGUNGSSATZ MOTOR KIT SOPORTE MOTOR 6 MOTORE MOTOR MOTEUR MOTOR MOTOR 11 16 17 19 KIT FILTRI Azzurri FILTERS KIT Blue KIT FILTRES Bleu FILTERSATZ KOMPLETT BLAU...

Page 21: ...del manual 6 Massa netta aspiratore Net weight of the unit Entl fternettomasse Masse nette aspirateur Peso neto del aspirador 4 Senso di rotazione della girante aspiratore Airfilter rotor rotation dir...

Page 22: ...150 5 168 125 M 8 10 20 30 D 3000 245 122 5 275 137 5 200 5 218 150 M 8 10 20 30 Montaggio orizzontale horizontal installation horizontale Ausrichtung montage horizontal montaje horizontal Mod A B C...

Page 23: ...LOSMA S p A Via E Fermi 16 24035 Curno BG Italia Tel 39 035 461444 Fax 39 035 461671 www losma it e mail info losma it...

Reviews: