• Connect the video cable on Channel 1 before Power
ON. The system will automatically detect electrical
settings as PAL or NTSC.
Bad picture quality after Power ON
• Set the Alarm Polarity according to whether your PIR
motion sensor is Normally Open or Normally Closed.
• If no motion sensors are connected, set that channel’s
Alarm Polarity to OFF.
Continuous Alarm
• Check the power source cord connections
• Check that there is power at the outlet
No Power
• If you are using a TV as a slave monitor, you may need
to set the channel as AUX (or sometimes referred to as
“TV / Video”).
• Please check if the wiring between the monitor and the
Quad Processor is correct.
• Make sure that the camera is receiving power
Unable to view cameras
REMEDY
PROBLEM
TROUBLESHOOTING
9
TECHNICAL SPECIFICATIONS
Because our products are subject to continuous improvement SVC reserves the right to modify product designs and specifications without notice and without incurring any obligations. E & O.E
Video input port
4 BNC camera inputs, 1 VCR input
Video output port
1 Quad output for VCR, 1 monitor output
Alarm input
4 (Normally High / Low selectable)
Alarm output
1 (Normally Open output)
Alarm duration
1 – 99 sec.
Camera Title
10 characters
Time / Date set
Built-in real time clock
Dwell Time
1 – 30 sec.
RS-232 port
Yes
Load impedance
75 Ohms
Operating environment
10~80%RH, 0
o
C~50
o
C
Power source
DC 12V
±
10%, 1A
Power consumption
6W maximum
Dimension (mm)
240(W) x 45 (H) x 150 (D)
Weight
1,300g