![Lord MicroStrain G-Link-LXRS User Manual Download Page 48](http://html1.mh-extra.com/html/lord-microstrain/g-link-lxrs/g-link-lxrs_user-manual_1939393048.webp)
G-Link
®
-LXRS
®
Wireless Accelerometer Node
User Manual
Troubleshooting
48
7.2
Device Status Indicators
The following is a complete list of the G-Link
®
-LXRS
®
status indicators.
Indicator
Symbol
Behavior
Node Status
Battery charge
source indicator
OFF
No power source detected
ON green
Charging source detected
Battery charged
indicator
OFF
Node not charging
ON bright red
Node battery charging
Completed
charge indicator
OFF
Node charge status unknown
ON green
Battery fully charged
ON green and
battery charging
indicator ON red
Battery fault condition. Reset
by unplugging power and then
plugging it back in
Device status
indicator
OFF
Node OFF or sleeping
OFF, with
occasional flash
Node sleeping with radio check
intervals enabled (default is
every 5 seconds)
Ten rapid flashes
when power is
initially applied
Node booting normally and
sending out a status message
1 second pulse
Node active and idle
Continuously ON
Node datalogging or streaming
data
1 Hz pulse green
Node is sampling in low duty
cycle or synchronized sampling
Pulses for each
ping
Node is sending out
communication requests (such
as in ping command, range
test, or EEPROM read/write)
Four to seven slow
pulses when power
is initially applied
Fault condition
Table 3 -
Device Status Indicators