- 39 -
Messages
10.15
17
Messages
17.1
Information and error messages HandyTIG 180 DC ControlPro
Code
Symptom
Cause
Remedy
H06
EEProm write/read error
Communication with EEProm faulty
Switch machine off and on again, exe-
cute master reset
E01
Thermal overload
Duty cycle exceeded
Allow switched-on machine to cool down
for a few minutes.
Fan defective
Switch unit off and on, fan must start up
for a short period, inform service.
E02
Power section
Power section start-up faulty
Inform Service
E03
Current sensor
Current sensor defective
Inform Service
E06
Overvoltage
Mains voltage too high
Check mains voltage
E07
Supply voltage 15V
Fault internal supply voltage
Inform Service
E10
Torch/remote control
Remote control, torch or connections
defective
Check or replace torch and remote con-
trol
E14
Control panel
Component group control panel faulty Inform Service
17.2
Error messages HandyTIG 180 DC BasicPlus
Symptom
Cause
Remedy
LED mains 37 and LED malfunc
-
tion 35 are not lit
mains fuse defect
exchange mains fuse
neutral, mains phase missing
check mains cable / mains extension cable
LED mains 37 is lit and LED mal
-
function 35 flashes
machine error
Turn off machine, wait until LED mains 12 is off,
turn machine on again If malfunction still persits,
contact Service
LED mains 37 is lit, but no welding
current
ground cable not connected or de-
fect
check ground cable, exchange if necessary
electrode holder or torch not con-
nected or defect
check electrode holder or torch, exchange if
necessary
LED malfunction 35 is lit con
-
stantly
machine is overheated, ED ex
-
ceeded
let machine cool down in standby