Technical data
- 53 -
04.19
909.1709.9-05
Technical data*
Units
Machine type
T 180 DC
ControlPro
T 220 DC
ControlPro
T 180 AC/DC
ControlPro
T 220 AC/DC
ControlPro
Mains
Mains voltage
V
230 / 1~
230 / 1~
230 / 1~
230 / 1~
Mains frequency
Hz
50 - 60
50 - 60
50 - 60
50 - 60
Positive mains tolerance
%
15
15
15
15
Negative mains tolerance
%
15
15
15
15
Mains connection
mm
2
3 x 2,5
3 x 2,5
3 x 2,5
3 x 2,5
Mains plug
Schuko
Schuko
Schuko
Schuko
Current input I1 no-load
A
0,26
0,26
0,26
0,26
Mains fuse slow-response TIG/EL
A
16
16
16
16
Phase angel cos φ I2 max
cos φ
0,97
0,99
0,97
0,99
Powerfactor λ at I2 max
λ
0,61
Max. permissible system impedance Zmax in
acc. with IEC 61000-3-11/-12
mΩ
23
140
23
140
Recommended generator performance
kVA
> 6,0 / 1~
> 6,0 / 1~
> 6,0 / 1~
> 6,0 / 1~
Machine
Protection class
IP
23S
23S
23S
23S
Insulation class
F
F
F
F
Cooling method
F
F
F
F
Noise emission
db(A)
< 70
< 70
< 70
< 70
Norm
EN 60974-1
EN 60974-1
EN 60974-1
EN 60974-1
Designation
CE, S
CE, S
CE, S
CE, S
Dimensions and weights
Dimensions power source (LxWxH)
mm
430 x 185 x 326
483 x 185 x 326
Weight of power source
kg
12,2
12,3
13,3
13,4
Tab. 8: Technical data
ED = Switch-on duration
*) measured at 40° C environmental temperature