20
Installation
(for qualified installers only)
© Travis Industries
4160713
100-01442
Rear Vent Configuration Vented into Stove with Co-Linear Adapter
•
Attach the Co-Linear adapter directly to the back of the stove. Use two (2) 3” UL 441 or 1775 gas
liners to vent the appliance through a code-conforming masonry or metal (zc) stove. All clearances to
combustibles must be met and the flex vent must be vented through a non-combustible stove
chimney.
•
Use a high-wind termination cap.
•
Vent height must be a minimum 10’ and maximum 25’.
•
Diffuser must be set to closed (#2) position.
•
Intake and exhaust restrictor must be set to the #1 (stock) position.
•
Do not install the intake damper plate or exhaust restrictor extender plates.
Liner Termination Kit
(Flashing and Adapter)
46DVA-GK
High Wind Termination
46DVA-VCH
Min. 18"
High-Temp.
Silicone
Co-Axial to Co-Linear Adapter
46DVA-TCL
3" (77mm) Dia. Flex Lines