16
Installation
(for qualified installers only)
© Travis Industries
4160713
100-01442
Exhaust Restrictor
NOTE: Refer to the vent configuration (pages 17 to 22) to determine the correct restrictor position.
Exhaust Restrictor Extender Plate
NOTE: Refer to the vent configuration (pages 17 to 22) to determine if the extender must be installed.
Diffuser
NOTE: Refer to the vent configuration (pages 17 to 22) to determine if the diffuser must be adjusted.
•
The diffuser is best accessed while converting the appliance to rear vent (see page 10).
Loosen these two screws
on the exhaust restrictor.
Slide the restrictor to the correct
restrictor position (see the illustration
below). The screw location indicates
restrictor position. In this example, the
restrictor is set in position # 3. Tighten
the screws to secure the restrictor.
(closed) # 5
# 4
# 3
# 2
(open - stock position) # 1
Back Wall of Firebox
Firebox Roof
Exhaust Restrictor Extender Plate
(found in the owner's pack)
Remove these two screws
on the exhaust restrictor.
Back Wall of Firebox
Firebox Roof
Use the screws to attach
the extender to the
exhaust restrictor.
Remove the
diffuser.
Before (Stock - Position # 1)
After (Position # 2)
DIFFUSER SIDE VIEW
Bend the round portion of the
diffuser so it is bent (position # 2).
Replace the
diffuser.
The diffuser is found on the inner flue assembly
(see Top to Rear Vent Configuration for details).
Bottom of inner
flue assembly
a
b
c