2. Safety instructions

A fog machine is not a toy!

•  Very hot steam escapes from the nozzle. Danger of getting burnt. 
•  Occasionally very hot droplets of fluid may escape when in operation. Thus never 

aim at persons directly and keep a minimum distance of 3 m to the nozzle.

•  Never touch the nozzle when in operation. Danger of getting burnt.
•  The  location  for  the  machine  must  be  non-flammable,  non-combustible  and  not 

sensitive to heat. It has to be twice as big as the machine.

•  Keep a minimum distance of 60 cm to all flammable, combustible objects and objects 

sensitive to heat.

•  Glycol is alcohol and burns with a slightly bluish, almost invisible flame. Never point 

the fog at strong sources of ignition like fire or pyrotechnic effects.

•  Never open the machine and leave the machine unattended when connected to a 

power supply.

•  It is only allowed to fly/hang the machine by using the original hanging set.
•  The visibility has to be more than 2 m in rooms where people walk around.
•  Do not swallow the fog fluid. Keep it away from children. In case of eye contact, 

rinse with a lot of water. Consult a doctor should you have accidentally swallowed 
some fluid.

•  Spilled fluid or splashed fluid droplets can cause slip hazard. Mop up the fluid and 

dispose of it according to regulations.

•  Fog may activate smoke detectors.

Artificially-made fog can be produced in many different ways. The method used here 
to produce fog, with a device which works according to the vaporizer principle, is the 
most harmless one. 
No case has so far been reported in which a sound human being has been harmed be-
cause of using our device to produce artificial fog. However, this can only be guaranteed 
if the professional fog generators are used accordingly, i.e. at the correct vaporization 
temperatures as well as with the correctly mixed fog fluid.

We, however, recommend: 

People with health problems or problems of the respiratory 

tract or with an inclination for allergies should avoid any contact with artificially-
made fog.

Summary of Contents for Viper NT

Page 1: ...TECHNICAL SERVICES FOR EVENTS THEATRE MUSIC EXHIBITION FILM TV 01483 757211 HIRE STORMLTD CO UK WWW STORMLTD CO UK...

Page 2: ...1 Operating manual a Look Solutions product viper nt...

Page 3: ...2 Set of Equipment supplied 1 Viper nt 1 tank lid with Quick Connector 1 manual Please check whether all the products you ordered are supplied Original operation manual version 05 2018...

Page 4: ...tting into operation 5 3 Switching the device off 5 4 Control choices 5 4 1 Control via DMX 512 5 4 1 1 Adjusting the DMX start address 5 4 2 Control via 0 10 Volt DC 5 4 3 Stand alone mode 5 4 4 Cont...

Page 5: ...pment and improvement of the Viper fog machine It unites the current digital technology with the proven technique and power of its predecessor New features guarantee a much more simple operation place...

Page 6: ...g set The visibility has to be more than 2 m in rooms where people walk around Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor...

Page 7: ...6 Rear view Front view 1 Nozzle CAUTION Hot Surface Avoid Contact Look Solutions VIPER NT 1 3 4 2 2 Fluid tube 3 Fluid tube inlet 4 Mains cable 3 Description of the parts...

Page 8: ...o be used with original Look fog fluid Use of other liquids will void the manufac turer s warranty and can be dangerous to your health Never use cleaner or fragrances with this machine Made by OTTEC T...

Page 9: ...2 Changing the fluid container Disconnect the fluid tube from the lid by pressing the brass collar 10 and removing the coupling 9 Remove the container from the tank housing of the Viper nt Unscrew the...

Page 10: ...to start The green Ready Led 22 blinks if the working temperature is reached As soon as the final temperature is reached the LED illumates permanently c Adjust the required output via the control pane...

Page 11: ...u Fig 1 Display shown at adjusting the pump output Fig 2 Display shown at adjusting the DMX start address Fig 3 Display shown at switching off the device 14 Mode button 15 Up Down buttons 16 Enter but...

Page 12: ...machine will change into the Timer Mode see point 5 5 a Connect the cable from the desk or the cable remote into the 3pin XLR socket at the back of the machine 8 b Adjust the pump level at 99 at the m...

Page 13: ...with the Up Down buttons 15 and press the Enter button 16 once to start the fogging process The machine now produces fog until the Enter button is pressed again The output can be changed during the fo...

Page 14: ...s the Mode button until you reach the required function With the Up Down buttons you can adjust the output Pxx fog time F xx and wait time P xx then press the Enter button to start the timer The timer...

Page 15: ...ew fluid into the old tank This reduces the changes of the machine clogging up If you install the Viper nt make 100 sure that a permanent fog free air supply for the unit is guaranteed Cooling air wit...

Page 16: ...d off due to overheating Remove external heat source for instance projector shining right onto the housing and or make sure sufficient fresh air supply After 15 to 30 minutes the unit should switch ba...

Page 17: ...gging time at 100 output approx 30 sec at 50 output continuous output external Fan max 800 Watt fan with one phase Air quantity adjustable in 99 steps Control DMX 512 0 10 V analog Timer Stand alone m...

Page 18: ...persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids other than original Look fog fluids have been used or if units are sent to us...

Page 19: ...d Men Standard Menu Menu Standard Timer start stop mit Pausenzeit Timer start stop with Pause 0 1 0 1 Timer start stop mit Nebelzeit Timer start stop with fog tim e 0 1 0 1 Timer Menu ESC Escape Timer...

Page 20: ...19...

Page 21: ...20 a Look Solutions product...

Reviews: