14
5. Operating the Viper nt
6. Cleaning, Care and Maintenance
– Ensure the air vents [5] are not clogged by dust. If necessary remove the dust.
– Take care that the machine can not get overheated.
– Do not run the
Viper nt
without any fluid, as the pump will run dry.
– Wipe up spiled Fluid immediately. Moisture – also fluid – can destroy the electric
parts of the machine.
– Check the state of the air valve filter from time to time and clean or replace it when
necessary. Always replace the whole fluid canister rather than pouring new fluid
into the old tank. This reduces the changes of the machine clogging up.
– If you install the
Viper nt
make 100% sure that a permanent fog-free air supply for
the unit is guaranteed. Cooling air with too high fog concentration (very often in
Clubs and Discos) can condense inside the machine and cause moisture damage.
– For cleaning the surface of the device use a suitable, solvent-free cleaner.
–
PLEASE NOTE
: The vaporizer of our machines does not have to be cleaned! Cleaners,
available on the market, can damage the vaporizer! We cannot grant warranty in
this case.
5.6 Wiring of the connectors
5pin XLR (DMX)
:
Pin 1 = Ground, Pin 2 = DMX –, Pin 3 = DMX +
3pin XLR (analog)
:
Pin 1 = Ground, Pin 2 = 0-10 V + DC in, Pin 3 = 12 V + DC out, max. 50 mA