8
OM-LKT-45G
feet on the kettle as needed and recheck level.
2.
For OPTIONAl Flanged Feet:
•
Obtain sufficient help or use material handling equipment to lift one side of
the kettle.
•
Use a heavy screwdriver and hammer (or mallet) to tap the adjustable
bullet feet out of the frame support legs. They are a tight press fit.
•
Position the optional flanged foot into the frame support leg and use the
hammer or mallet to seat the flanged foot. Don’t bend the floor flange
when seating the foot.
NOTE
: Flanged feet are height adjustable and can be leveled by following
the Kettle Leveling Instructions on page 7. After the Kettle is positioned as
desired and leveled, the flanged feet can be secured with floor anchors,
per local codes and best practice.
mAKE ElECTRIC POwER CONNECTION
1. Provide 120 VAC, 60 Hz, 1 Ph, 3 Amp electrical service for standard unit. Use 1/2
inch waterproof conduit and waterproof connections. A cutout is provided in the
back of the control panel enclosure, just above the gas pipe nipple.
ImPORTANT
: Observe local codes and/or The National Electrical Code in
accordance with ANSI/NFPA-70 latest edition. In Canada, provide electrical
service in accordance with the Canadian Electrical Code CSA C22.1 Part 1 and/
or local codes.
2. AN ELECTRICAL GROUND IS REQUIRED. The electrical schematic is located on
the inside of the service panel and on page 25 of this manual.
mAKE gAS CONNECTION
1. The internal gas lines of the unit were cleaned and closed off with a gas cock
before the unit was shipped from the factory.
ImPORTANT
: Free external gas
lines of lint, dirt, metal chips, sealant, grease, oil, and other contaminants before
you connect the lines to the kettle.
2. Connect the gas cock of the kettle to the gas service main with 1/2 inch IPS line
or approved equivalent.
ImPORTANT
: Installation must conform with local codes or with the American
National Standard Z223, latest edition, National Fuel Gas Code. In Canada,
installation must conform to CAN/CGA B149 Installation Codes for Gas Appliance
and Equipment and/or local codes. Do NOT obstruct the flue or vent duct after
installation.
3. After the kettle has been connected to the gas supply, all gas line joints must be
checked for leaks. DO NOT USE A FLAME TO CHECK FOR LEAKS. A thick soap
solution or other suitable leak detector should be employed.
Installation Instructions
PRESSURE TEST wARNINg
1. During pressure testing of the gas supply
piping system at pressure exceeding 0.5 PSIG,
the kettle and its individual shutoff valve must
be disconnected from the gas supply piping
system.
2. During pressure testing of the gas supply
piping system at pressures equal to or less
than 0.5 PSIG (3.45 kPa), the kettle must be
isolated from the gas supply piping system by
closing its individual manual shutoff valve.
ElECTRICAllY gROUNd ThE UNIT AT ThE
TERmINAl PROvIdEd. FAIlURE TO gROUNd
ThE UNIT COUld RESUlT IN ElECTROCUTION
ANd dEATh.
dO NOT CONNECT ANY PIPINg TO ThE POP
SAFETY vAlvE. ThE vAlvE mUST bE FREE
TO vENT STEAm AS NEEdEd. ImPROPER
INSTAllATION wIll vOId ThE wARRANTY!
ThE ElbOw ATTAChEd TO ThE SAFETY
vAlvE mUST POINT TO ThE FlOOR.