Page 26
The Lohberger Pellet module was successfully tested by the Technical University
of Vienna according to the current European Standards.
Test report number:
TGM-VA HL 7813
The appliance is in conformance with the emission values according to art.15a
B-VG (Austrian law) for protective measures and energy saving. Furthermore,
amongst others the following exhaust gas limits according to the following
German standards are complied with: Regensburger Norm, Stuttgarter Norm
and Münchner Verordnung.
Table 4
AC 105
F3+B3
Fuel fi lling door opening
Width x height
mm
185 x 245
Fuel fi lling space
Width x depth
mm
233 x 405
Fuel fi lling height
grate top /bottom position
mm
100 / 250
Oven
Width x height x depth
mm
420 x 290 x 410
Cooking surface
Width x depth
mm
1008 x 507
Area
m
2
0,51
Ash drawer
Stove
litre
4,5
Fuel storage container
Stove
litre
34,5
Fuel consumption
Heat output min./ max.
kg / h
2,3 / 3,8
Central heating insert
Water content
litre
25
Operating pressure
Max.
bar
3
Operating temperature
Max.
°C
95
Baking tray
Width x depth
mm
400 x 400
Baking tray / Grid
Width x depth
mm
400 x 400
Weight
packaging included
kg
345
Packaging
kg
ca. 30 – 40
Output data:
Data for chimney calculation
Rated heat output / Full fi ring
wood / lignite
kW
14 / 13,5
Water heating capacity
wood / lignite
kW
10,5 / 9,5
Room heating capacity
wood / lignite
kW
3,5 / 4
Rated heat output / Shallow fi ring
wood
kW
8,8
Water heating capacity
wood
kW
7,5
Room heating capacity
wood
kW
1,3
Flue gas temperature
wood / lignite
°C
182 / 160
Flue gas mass fl ow rate
wood / lignite
g/s
11,3 / 11,9
Required draught pressure
wood / lignite at rated heat output
mbar
0,20 / 0,21