USER MANUAL SMARTneo //
PAGE 37
Number
Description
Remedy
00
Internal error channel 1
Switch off the motor control unit. Con-
tact the customer service.
01
Internal error channel 2
12
Defect channel 1
Disconnect the motor control unit.
Remedy the external short circuit.
or
Plug in the correct motor at the affected
bushing. Put the motor control unit into
operation again.
13
Defect channel 2
24
Overcurrent motor M1
Remove the clamped objects from the
travel range.
Table overload -> Remove the load from
the table.
Contact the customer service.
25
Overcurrent motor M2
48
Overcurrent motor group 1
60
Collision protection
62
Overcurrent of the control
36
Plug detection at motor bushing M1
Plug in the correct motor at the affected
bushing.
Carry out a manual reset.
37
Plug detection at motor bushing M2
61
Motor replaced
55
Synchronisation of motor group 1 not
possible
Remove the load from the table.
Carry out a manual reset. If the error is
still displayed after the manual reset,
contact the customer service.
60
Collision protection
Remove the clamped objects from the
travel range. Table overload -> Remove
the load from the table.
Contact the customer service.
71
Changing the anti-pinch configuration
Refer to the DMS sensor manual in order
to activate or deactivate the anti-pinch
configuration
67
Voltage too high
Disconnect the power supply cable and
contact the customer service.