USER MANUAL SMARTneo //
PAGE 26
Proceed as follows to
deactivate
a container stop / shelf stop position:
Put the table top in a random position in the lower half of the travel range in order to
deactivate the container stop. Put the table top in a random position in the upper half of
the travel range in order to deactivate the shelf stop.
Use the buttons
Table top down
or
Table top up
until the required position is reached.
SAVE
Press S for 10 seconds. The control clicks
once
when the position is saved.
or
&
simultaneously
With hand control equipped only with up and down button, the function can be carried
out by pressing both the up and the down button simultaneously for 10 seconds.
NOTICE
These steps must be carried out separately for a container stop
position and for a shelf stop position.
10.4 PLUG DETECTION
The motor control unit SMARTneo detects whether a motor is connected to the respective motor bushing.
The motor control unit also detects whether a motor was replaced (the availability of this function depends
on the control type and the drives used). When a motor is missing or was replaced, the SMARTneo clicks
three times. The display also shows an appropriate error code if the hand control is equipped with a display.
Proceed as follows to remedy the error:
Possible situations:
A motor was removed from the SMARTneo while the control was connected to the power
supply system.
E38
Error code
E36, E37 or E38
is shown on the hand control display depending on which
motor was removed.
Disconnect the power supply of the SMARTneo and wait at least 5 seconds.
Reconnect the missing motor.
Reconnect the power supply of the SMARTneo.
Carry out a
manual reset