USER MANUAL SMARTneo // 

PAGE 9

DANGER

Danger due to inactive collision protection

With all reset processes (Chapter 9.4 Manual reset), the collision 
protection (ISP) is inactive. Please note the increased crushing 
hazard hereby!

DANGER

Remove from the electricity network before cleaning

The motor control unit must be cleaned exclusively with a dry, 
soft cloth. Before cleaning, you must pull the power supply cable 
from the mains plug without fail.

DANGER

Cleaning by children without a supervision

Cleaning may not be carried out by children without supervisi-
on.

DANGER

Danger of crushing

There is a crushing hazard if the table top position is changed. 
Therefore make sure that there are no items or persons in the 
danger zone and that no one reaches into the danger zone.

WARNING

Increased safety risk

The firmware is delivered with deactivated double-click func-
tion. If you activate the function, the grading of the safety 
functions according to EN ISO 13849-1 PL b, Category B, loses its 
validity. The legal requirements from the standard are no longer 
met with this function. 
To use the double-click function, you have to carry out a new 
assessment of the higher safety requirements according to EN 
60335-1 which cannot be met by this product. LOGICDATA is not 
liable for injuries or damage which can result from the activation 
of the double-click function.

DANGER

Various dangers when exceeding the carrying capacity

Ensure that the maximum load of the table specified by the table 
manufacturer is not exceeded.

DANGER

Use compatible hand control

For the HV socket, use only HSC-OV-MDF-4M2 or LOGICDA-
TA-compatible hand control cables. Especially LAN cables or 
comparable cables must not be connected to the control unit.

Summary of Contents for SMARTneo Series

Page 1: ...User Manual Document Version 2 0 October 2018 SMARTneo...

Page 2: ...ations 6 2 2 Residual hazards 6 2 3 Qualified persons 10 2 4 Liability 10 3 Product 11 3 1 Description 11 3 2 Intended use 13 4 Delivery scope 13 5 Unpacking 13 6 Assembly 14 7 Commissioning 16 7 1 Co...

Page 3: ...t Number of Drives 27 10 6 Detection of SLIMdrive drives 27 10 7 Duty cycle monitoring 28 10 8 Change of the display unit cm or inches 29 10 9 Changing the number of motors 30 10 10 Control system to...

Page 4: ...ritten consent of LOGICDATA LOGICDATA reserves the right to make changes to the specifications and other information in this documentation without prior an nouncement 1 2 ROYALTY FREE USE OF IMAGES AN...

Page 5: ...AND SIGNAL WORDS USE DANGER Imminent threat to the lives of individuals Warns against a dangerous situation Failure to observe the war ning will result in death or severe personal injury WARNING Risk...

Page 6: ...may carry out work on the system The national employee protective conditions as well as national safety and accident prevention regulations apply to system operation 2 2 RESIDUAL HAZARDS Even with ma...

Page 7: ...or a lack of experience and knowledge if they are supervised or were instructed in the safe use of the device and understand the resultant hazards Children may not play with the device DANGER Danger i...

Page 8: ...e may otherwise be damaged or destroyed DANGER Remove from the electricity network before plugging Before plugging hand control in and out you have to pull the power supply cable from the mains plug w...

Page 9: ...nger zone WARNING Increased safety risk The firmware is delivered with deactivated double click func tion If you activate the function the grading of the safety functions according to EN ISO 13849 1 P...

Page 10: ...ystem and is responsible for the certification of the overall system 2 4 LIABILITY The information in this documentation describes the characteristics of the products without assuring them The product...

Page 11: ...ssible in Europe Two motors can be actuate to the control Two controls can be connected to one cascading cable LOG CBL SMARTneo SYNC 1000 in order to actuate up to four motors SMARTneo 2 YYY US Design...

Page 12: ...r another LOGICDATA hand control LOGIClink 1 mains cable two pin connection C8 Four engined table 2 controls SMARTneo 1 cascading table 4 actuators e g SLIMdrive 500 SLIMdrive 660s 1 hand control e g...

Page 13: ...and the resultant hazards Children may not play with the device Cleaning may not be carried out by children without supervision After the mechatronic system has been installed in a table the table man...

Page 14: ...disconnected from the mains plug WARNING Acclimation of the product Before mounting and commissioning the SMARTneo make sure that the product acclimatizes to the temperature and humidity values speci...

Page 15: ...USER MANUAL SMARTneo PAGE 15 Fig 2 drilling template...

Page 16: ...ing only by knowledgeable staff Commissioning of the motor control unit may be carried out only by knowledgeable technical staff Knowledgeable technical staff has the necessary electrotechnical traini...

Page 17: ...nformation regarding the cascading please refer to the operating instructions for the cascading of motor controls Operating instructions are available in the download area of the homepage www logicdat...

Page 18: ...llel to the basic level In addition the control stores the connected components in the standard version After the reset configuration changes are detected and rated as errors The system no longer move...

Page 19: ...or if you are absent for a longer period of time pull the power supply cable out of the socket Otherwise device damage may be caused by network related overvoltage The motor control unit SMARTneo pro...

Page 20: ...e the button or the maximum or minimum table top height has been reached DANGER Danger of crushing There is a crushing hazard if the table top position is changed Therefore always make sure that there...

Page 21: ...function to adjust a saved table top position Proceed as follows to adjust a saved table top position NOTICE Availability of the double click function depends on the software configuration of the moto...

Page 22: ...osition again DANGER Increased safety risk The firmware is delivered with deactivated double click func tion If you activate the function the grading of the safety functions according to EN ISO 13849...

Page 23: ...ed crushing hazard hereby 9 5 CORRECTING THE HEIGHT DISPLAY With this function you can change the height display on the display but not the table top position of the table top This function is availab...

Page 24: ...are reached Highest and lowest table top position All saved positions e g memory positions container stop position 10 2 SAFETY AREA This function causes a safety stop at a defined table top position c...

Page 25: ...tion Put the table top in the position that you want to use as new container stop shelf stop position Use the buttons Table top down or Table top up until the required position is reached SAVE Press t...

Page 26: ...container stop position and for a shelf stop position 10 4 PLUG DETECTION The motor control unit SMARTneo detects whether a motor is connected to the respective motor bushing The motor control unit al...

Page 27: ...SMARTneo can automatically detect the type of connected SLIMdrive drives it can thus be determined during commissioning whether it is a SLIMdrive 500 or a SLIMdrive 660S drive In order to be able to...

Page 28: ...ends on the settings in the software parameters of the SMARTneo Please contact LOGICDATA for additional informa tion NOTICE If the number or type of connected drives changes the control must be reset...

Page 29: ...hen release the buttons S 7 The display shows S and a number e g S 7 Press the button Table top up until the display shows S 5 S 5 The display shows S 5 SAVE Press the memory button If the display was...

Page 30: ...ry position buttons 1 2 and the button Table top up Hold the button combination for approx 3 seconds Then release the buttons S 5 The display shows S and a number e g S 5 Press the button Table top up...

Page 31: ...y press the memory position buttons 1 2 and the button Table top up Hold the button combination for approx 3 seconds Then release the buttons S 5 The display shows S and a number e g S 5 Press the but...

Page 32: ...op up and Table top down Keep holding this button combination Keep holding this button combination Table top down and Table top up while you con nect the control to the power supply Keep holding this...

Page 33: ...ction ISP please note the following requirements In order to ensure the best possible collision protection a me chanical brake must be integrated that is effective on the down movement of the height a...

Page 34: ...shutdown but the interoperati on of mechanical equipment and electronics Furthermore the shutdown sensitivity is influenced by mechanical equipment motor and environmental conditions LOGICDATA as con...

Page 35: ...ectricity failure during the run or power supply cable disconnec ted during the run Manual reset Motor control unit defective Contact the customer service Hand control defective Replace the hand contr...

Page 36: ...erheating protection This overheating protection at activated because of overheating Wait until the motor control unit has cooled off and the message HOT on the display goes out The motor control unit...

Page 37: ...60 Collision protection 62 Overcurrent of the control 36 Plug detection at motor bushing M1 Plug in the correct motor at the affected bushing Carry out a manual reset 37 Plug detection at motor bushi...

Page 38: ...l cable connections and try to carry out a drive reset If the drive reset is not possible dis connect the power supply of all controls Wait for at least 5 sec and connect all controls with the power s...

Page 39: ...tion 2x Normal operation The system is working without problems 1x Emergency operation The system is in emergency operation mode the drives cannot be used Check the LEDs and or the error code on the d...

Page 40: ...nic device which must be disposed of separately from household trash in accordance with the WEEE guideline 2012 19 EU The products are labelled with the symbol shown on the left Before the disposal of...

Page 41: ...k 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 E mail office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 1525 Gezon Parkway SW Suite...