1.  Preface 

Dear customer, 
 
Thank  you  for  choosing  a  LogicSP-2-1  /  LogicSP-2-2  motor  control  box  for  height  adjustable 
TV-Set Carriers from LOGICDATA GmbH. You have purchased a state-of-the-art product which 
complies with all safety requirements. 

1.1.  Appropriate Operation 

LogicSP-2-1  /  LogicSP-2-2  motor  control  boxes  must  solely  be  used  for  the  intended 
application,  control  of  height-  and  angle-adjustable  TV-Set  Carriers.  (Such  as  the  LiftBox™ 
system.) Use only motors that meet the specifications of LOGICDATA GmbH to drive the lifting 
column  and  for  rotating  the  TV-Set  Carrier.  (The  rotation  function  is  available  only  in  the 
LogicSP-2-2  control  box.)  The  control  box  must  be  installed,  initially  operated  and  functional 
tested  by  competent  personnel  only.  Use  other  than  described  above  is  only  allowed  with 
permission of LOGICDATA. The basic functionality is up/down movement of the TV-Set Carrier 
(doable with any LOGICDATA handset). 

1.2.  Functionality LogicSP-2-1 / LogicSP-2-2 

The  motor  control  boxes  LogicSP-2-1  /  LogicSP-2-2  offer  following  functionality  and 
performance characteristics (however, the practical applicability of these functions depends on 
the used handset and the connected motors): 

 

Control boxes are available for different mains voltages 

 

All 

LOGICDATA

 handsets are utilizable optionally 

 

Depending on the type of handset used, additional functionality (e.g. right/left rotation for the 
Rotation-LiftBox™) is available 

 

ISP (Intelligent System Protection)

 

 

Configurable stop conditions (overtemperature, overcurrent, timeout, limit switches) 

 

Configurable reset conditions 

 

Configurable duty cycle 

 

1 or 2 independently controlled motors 

 

Hall-Sensor configuration per motor group (1, 2 or differential hall-sensors) 

 

Plug Detection 

 

1 Memory Position per Motor 

 

Additional pinch-protection with squeeze line 

 

Drive-Back function on various conditions 

 

Remote Controlled 

 

TV-Overheating Protection 

1.3.  Audience and Previous Knowledge 

This user manual is intended for the following audience: 

 

Assembly  personnel:  Technicians  who  assemble  and  start  up  the  height-adjustable  TV-Set 
Carrier system (mount control box and motors, configure the control box, etc.). 

 

Furniture  assembly  personnel,  service  personnel,  which  puts  the  height-adjustable  TV-Set 
Carrier system into operation on site in showrooms or directly at the end customer's place. 

To put into operation, mount and configure height-adjustable TV-Set Carriers with the LogicSP 
control box, following skills are prerequisite: 

 

Basic mechanical and electronics skills 

 

Lecture of this manual 

Summary of Contents for LogicSP-2-1

Page 1: ...lity and specifications are subject to change without prior notice LOGICDATA assumes no liability for damage caused by improper use of the products described herein LOGICDATA will at point of delivery...

Page 2: ...1 TV Set Carrier Upwards 16 4 1 2 TV Set Carrier Downwards 16 4 1 3 TV Overheating Protection 16 4 2 Advanced Functionality 17 4 2 1 Saving a Viewing Position 17 4 2 2 Accessing the Viewing Position 1...

Page 3: ...User Manual LogicSP 2 1 LogicSP 2 2 Page 3 of 29...

Page 4: ...User Manual LogicSP 2 1 LogicSP 2 2 Page 4 of 29...

Page 5: ...depends on the used handset and the connected motors Control boxes are available for different mains voltages All LOGICDATA handsets are utilizable optionally Depending on the type of handset used add...

Page 6: ...ad to even fatal injury and damage your property Caution This safety instruction warns of dangerous voltage levels Neglecting this advice may lead to possibly lethal injuries and or damage to your pro...

Page 7: ...ting Link and TV Power Cable built into the Control Box 2 Mounting Plate 3 Mains Cable Note For detailed information on optional control components and accessories see the section about Optional Acces...

Page 8: ...l Safety Instructions Note Carefully read the user manual before you mount operate the LogicSP control box Caution Do not open this unit Risk of electric shock Caution Do not exceed the duty cycle pri...

Page 9: ...uise hazard may be present Danger Any modification of the control box control elements and handsets is prohibited Danger Do not operate the unit in the vicinity of explosives or easily combustible sub...

Page 10: ...ment upper left hand side as shown in the images below Fig 2 Placement of the LogicSP Control Box in the LiftBox System Following tools are needed for installation 1 screw driver for recessed head scr...

Page 11: ...ng plate 4 Align the mounting plate with the pencil line and mark the two drill holes 5 Pre drill these 2 holes 6 Fix the mounting plate with 2 screws in the pre drilled holes Fig 4 Mounting the Logic...

Page 12: ...holes 11 Screw the remaining 2 screws about halfway into the pre drilled holes Fig 7 Mounting the LogicSP Control Box Step 11 12 Attach the control box again 13 Slide the LogicSP control box onto the...

Page 13: ...ig 9 LogicSP Interfaces 1 Interface to Motor 1 up down 2 Interface to Motor 2 right left only in the LogicSP 2 2 3 TV Power Cable 4 Interface to Alternative Handset the LogicSP Control Box usually com...

Page 14: ...is used to implement pinch protection for downwards and or upwards movement connect it to the interface SL see Fig 9 port 5 As mentioned above if a built in foil handset is used connecting an alternat...

Page 15: ...LiftBox in this example 3 Motor drive for up down movement integrated in the lifting column 4 Motor drive for right left rotation 5 Squeeze Line for pinch protection during downwards movement 6 TV Po...

Page 16: ...oned above the functionality described in this section can be accessed with any LOGICDATA handset The icons used here for illustration purposes are taken from the LiftBox custom foil handset LOG KM LI...

Page 17: ...mode Once you have reached the desired viewing position press SETUP again to save it The new viewing position is now stored 4 2 2 Accessing the Viewing Position If a viewing position is stored Pressi...

Page 18: ...le to rotate the carrier above the rotation level When saving a viewing position that is above the rotation level the angle position will be saved along with it When such a viewing position is accesse...

Page 19: ...y and then the BYPASS key and hold them for at least 3 seconds until the LED is flashing quite fast The control box is now in BYPASS mode until the SETUP key is pressed again Note that BYPASS mode is...

Page 20: ...east 5 seconds in step 2 4 3 Software Dependent Functions Note Prior to delivery the LogicSP control box is programmed with a set of parameters appropriate for the intended application The functions d...

Page 21: ...lock the direction guarded by the squeeze line Example If a squeeze line is used to implement pinch protection for downwards movement and you unplug it the carrier will refuse to move downwards Except...

Page 22: ...intervals Press the UP key Release the key and immediately press it again The control box will adjust the speed of the upwards movement according to the length and frequency of the brief pauses betwe...

Page 23: ...Terminal I Protection Class without Grounding Terminal II Mains Cable 3m Dimensions L W H 214x109x62mm 5 1 1 European Versions All European versions share the same supply voltage requirements Supply V...

Page 24: ...on on the control box Note Specifications on your LogicSP motor control box vary depending on the version of the device and its firmware revision Refer to the LogicSP datasheet for a detailed descript...

Page 25: ...e handset Exchange the handset If the problem appears to be the built in foil handset contact our customer service Drives move only in one direction Possible Cause Solution Defective control box Conta...

Page 26: ...again The display reads E followed by a two digit number Possible Cause Solution An internal error occurred Proceed according to the following table Code Description Solution 00 No error 01 Relay of m...

Page 27: ...r supplier 54 Total Current cutoff Restore power to the control box 55 Motor 1 not connected 56 Motor 2 not connected Connect a motor to the corresponding socket 60 Pinch Protection Squeeze Line not c...

Page 28: ...SP 2 2 Page 28 of 29 6 4 Drill Template To speed up installation of the LogicSP motor control print this page on A4 paper and cut out this drill template to mark the drill holes for mounting the contr...

Page 29: ...box Note Dispose of the components ecologically sound separate plastic from electronics parts This applies to components like squeeze line drives cables etc as well 7 2 Contact LOGICDATA LOGICDATA El...