background image

LOGICLINK - MANUAL // PAGE 2

LOGIClink - Operating Manual
Document Version 2.0 / April 2019
This document was originally published in English. 

LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria

Phone:

+43 (0) 3462 51 98 0

Fax:

+43 (0) 3462 51 98 1030

Internet:

http://www.logicdata.net

Email:

[email protected]

Summary of Contents for LOGIC OFFICE Series

Page 1: ...MANUAL Document Version 2 0 April 2019 LOGIClink Valid for LOGIClink Corporate LOGIClink Personal Standard LOGIClink Personal Lite Motion Work App...

Page 2: ...0 April 2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51...

Page 3: ...5 Explanation of symbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 10 4 Unpackaging 10 5 Products 11 5 1 Key Product...

Page 4: ...onnecting the LOGIClink 22 7 5 3 Next Steps 22 7 6 Marking the NFC Reading Area 23 8 Operation Manual 24 8 1 Adjusting the Table Top Height 24 8 2 Restart 25 8 3 Factory Reset 25 9 Operation via the A...

Page 5: ...After purchase and full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user d...

Page 6: ...range of Connectivity Hubs for Height Adjustable Table systems There are three versions of the LOGIClink Corporate Personal Standard and Personal Lite The products are installed by Resellers into Hei...

Page 7: ...ce Protection Class III Protection Class III devices may only be connected to SELV or PELV power sources INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply...

Page 8: ...on heated surfaces Check the housing and Cables of the LOGIClink for visible damage Do not install or operate damaged products WARNING Risk of death or serious injury in explosive atmospheres Operati...

Page 9: ...ty and product safety Resellers should provide end users with an Operating Manual in their native EU official language INFO The Charter of the French Language La charte de la langue fran aise or Bill...

Page 10: ...r ESD handling during unpackaging Damage that can be attributed to electrostatic discharge will void warranty claims Always wear an anti static wristband To unpackage the product 1 Remove all componen...

Page 11: ...ccompanying data sheet to check ensure that you have received the correct variant 5 1 KEY PRODUCT FEATURES 1 NFC Area LOGIClink Corporate and Personal Standard Only 2 Wi Fi Communication Module LOGICl...

Page 12: ...below is an example LOGIClink Personal Standard The design of the shutter depends on the configuration of the LOGIClink you have ordered The outer dimensions of the LOGIClink are the same for all vari...

Page 13: ...LOGICLINK MANUAL PAGE 13 5 3 DRILLING TEMPLATE Fig 3 Drilling Template LOGIClink Front Edge Side Edge 1 593 40 45 mm 4 409 112 0 mm 3 425 87 0 mm...

Page 14: ...of minor or moderate injury through tripping During assembly and operation poorly routed Cables may become a trip hazard Tripping over Cables may lead to minor or moderate injury Ensure that Cables a...

Page 15: ...e that the Signal LEDs can be seen from the front of the table INFO LOGICDATA recommends placing the LOGIClink roughly 70 cm from the user s normal sitting position 1 Mark the position of the drilling...

Page 16: ...the user s right hand side turn the sensor towards R If the LOGIClink will be on the user s left hand side turn the sensor towards L Fig 5 Aligning the Presence Sensor 6 3 3 COMPLETING ASSEMBLY After...

Page 17: ...ontact LOGICDATA before connecting the LOGIClink in order to confirm compatibili ty Failure to comply is classified as misuse and will void warranty claims The following products are compatible with L...

Page 18: ...system setup if one or more of the following conditions apply You will connect an additional Handset to the LOGIClink You will connect the LOGIClink to a COMPACT e or SMART e Control Box was produced...

Page 19: ...to minor or moderate injury through electric shocks Do not connect the Control Box to the Power Unit before the LOGIClink has been safely connected 1 Insert the LOG CBL LOGICLINK CB STANDARD Cable int...

Page 20: ...does not supply this accessory and cannot provide guarantees regarding quality safety or performance 7 4 2 CONNECTING THE LOGICLINK CAUTION Risk of minor or moderate injury through electric shocks Co...

Page 21: ...GIClink is connected assembly differs depending on the version of LOGIClink you have in stalled LOGIClink Corporate and Personal Standard Go to Chapter 7 6 Marking the NFC Reading Area All other varia...

Page 22: ...ables while the DYNAMIC MOTION system is connected to the Power Unit may lead to minor or moderate injury through electric shocks Do not connect the DYNAMIC MOTION system to the Power Unit before the...

Page 23: ...chapter 1 Locate the NFC Reading Area on the table top The Reading Area should be a 60 x 6o mm square directly over the LOGIClink 10 mm from the back edge Fig 7 2 Ensure the Reading Area is positioned...

Page 24: ...LOGICDATA Control Boxes and the DYNAMIC MOTION system Before using a Control Box connected Table System you must also read the Operating Manual for the installed Control Box including all relevant sa...

Page 25: ...e System from the Mains by removing the plug 2 Press and hold the UP and DOWN Keys 3 While holding the UP and DOWN Keys reconnect the Table System to the Mains The LEDs will flash LOGIClink Corporate...

Page 26: ...e from the Google Play Store Android and the App Store iOS 9 2 PAIRING SMART DEVICES WITH LOGICLINK CAUTION Risk of minor or moderate injury through uncontrolled movement It is possible that more than...

Page 27: ...the screen to begin pairing Tap Scan and Connect to find your LOGIClink Select the correct LOGIClink from the list of available devices When prompted tap Pair and Connect to pair with LOGIClink Enter...

Page 28: ...ects are kept away from the edge of the table Do not leave unnecessary objects on the table during movement 9 3 1 ADJUSTING THE TABLE TOP HEIGHT CAUTION Risk of minor or moderate injury through crushi...

Page 29: ...or Standing to save the position The Memory Position has been saved Fig 10 Saving a Memory Position 9 3 3 ADJUSTING THE TABLE TOP TO A SAVED MEMORY POSITION This function allows you to move the Taple...

Page 30: ...ctivated auto movement function If you activate this function the grading of the safety functions according to EN ISO 13849 1 PL b Category B are no longer valid as the legal requirements in the stand...

Page 31: ...uthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards Only use accessory parts produced or approved by LOGICDATA Only use replacement parts p...

Page 32: ...ftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc Broadmoor Ave SE Suite...

Reviews: