BURNER SPECIFICATIONS
Gas type:
Butane
G30 -
Nominal pressure
=28-30mbar
Propane
G31
-
Nominal pressure
=37mbar
HOB
GLASS
Methane
G20
-
Nominal pressure
=20mbar
Type of burner
By
pass
Ø
1/100
mm
Liquid gas/LPG
Natural gas
Injectors
Ø
1/100
mm
Nominal thermal capacity
Inje
ctor
Ø
1/10
0
mm
Nominal
Thermal
capacity
kW
max
g/h max
kW
min
g/h min
G30
G31
G30
G31
kW
max
kW
min
Cooking hob burners III series
Auxiliary (small)
27
52
1,10 79
78
0,35 25
25
73
1,10 0,35
Semi
– rapid: (medium)
31
65
1,75 127
125
0,45 32
32
98
1,75 0,45
Rapid: (large)
42
82
2,80 203
200
0,75 54
53
122
2,80 0,75
Treble crow
60
97
3,70 268
264
1,50 109
133
133
3,70 1,50
HOB
INOX
Type of burner
By
pass
Ø
1/100
mm
Liquid gas/LPG
Natural gas
Injectors
Ø
1/100
mm
Nominal thermal capacity
Inje
ctor
Ø
1/10
0
mm
Nominal
Thermal
capacity
kW
max
g/h max
kW
min
g/h min
G30
G31
G30
G31
kW
max
kW
min
Cooking hob burners III series
Auxiliary (small)
27
52
1,10 79
78
0,35 25
25
73
1,10 0,35
Semi
– rapid: (medium)
34
65
1,75 127
125
0,55 36
36
98
1,75 0,55
Rapid: (large)
44
82
2,80 203
200
0,85 60
59
122
2,80 0,85
Treble crow
65
97
3,50 260
258
1,50 109
133
133
3,50 1,50