12
Installation and Startup
FALCON-i
Plug M8
male
(front view)
brown
black
white
PNP-Output
(I = 2.7 mA constant)
blue
GND
800ms
6..8ms
24VDC
NPN-Output
(I Max. = 25 mA)
3.3 Connections
3.4 Connection Diagram
Plug M8
male
(front view)
brown
black
white
PNP-Output
(I = 2.7 mA constant)
blue
GND
800ms
6..8ms
24VDC
NPN-Output
(I Max. = 25 mA)
Risk of fatal injury from electric current!
Z
External circuits shall be double insulated from mains.
DANGER