13
Installation and Startup
FALCON-i
3.5 Mounting and
Adjustment
When mounting the optical yarn defects sensors FALCON-i, the following
must be observed:
Do not position the equipment such that it is difficult to disconnect the
M8 plug.
The yarn should run as smoothly as possible through the sensor.
The yarn must be slightly deflected by the white ceramic yarn guide (1).
By moving the outer yarn guide (2), an additional yarn calming can be
achieved.
1
2
2