11

Installation and Startup

FALCON-i

Risk of injuries! 

Work on the running machine may lead to severe personal 
injury. 

 

Z

Stop the machine and wait until the machine has come 
to complete standstill. 

 

Z

Only perform work on electrical components when these 
are switched off, disconnected from the mains and po-
tential-free.

 

Z

Prior to start-up verify if all appropriate covers are  
mounted.

 

Z

Prior to start-up perform safety check.

WARNING

3  Installation and Startup

3.1  General

3.2  Safety

Installation and start-up may only be performed by authorized and trained 
personnel.

Yarn guide

Yarn guide

Digital display 

Sensor
Function button

Yarn guide ceramic

Summary of Contents for WEFTMASTER FALCON-i

Page 1: ...WEFTMASTER FALCON i Optical Yarn Defects Sensor Fitting and Service Manual 46875003 en Version 1 02 05 2014...

Page 2: ......

Page 3: ...instruction manual is copyrighted and exclusively meant for internal purposes Disclosures to any third party or reproduction of any kind even in form of excerpts as well as the use and or disclosure o...

Page 4: ......

Page 5: ...2 Safety 9 2 1 Responsibilities 9 2 2 Personnel Requisitions 9 2 3 Usage 9 3 Installation and Start up 11 3 1 General 11 3 2 Safety 11 3 3 Connections 12 3 4 Connection Diagram 12 3 5 Mounting and Ad...

Page 6: ......

Page 7: ...n this manual must be included In these instructions safety information is marked with symbols and signal words which point out the extent of the hazard The safety information has to be strictly obser...

Page 8: ...following occurrences Unauthorized rebuilds or modifications of the optical yarn defects sensor Usage of unauthorized spare parts reproductions modification parts not provided by Loepfe Brothers Ltd 1...

Page 9: ...task areas Foreman and User are qualified and trained staff for the operation and maintenance of the optical yarn defects sensor Installation Engineer and Service Engineer are qualified personnel bei...

Page 10: ......

Page 11: ...trical components when these are switched off disconnected from the mains and po tential free Z Z Prior to start up verify if all appropriate covers are mounted Z Z Prior to start up perform safety ch...

Page 12: ...blue GND 800ms 6 8ms 24VDC NPN Output I Max 25 mA 3 3 Connections 3 4 Connection Diagram Plug M8 male front view brown black white PNP Output I 2 7 mA constant blue GND 24VDC NPN Output I Max 25 mA R...

Page 13: ...following must be observed Do not position the equipment such that it is difficult to disconnect the M8 plug The yarn should run as smoothly as possible through the sensor The yarn must be slightly d...

Page 14: ...14 Installation and Startup FALCON i 3 6 Possible Mounting Positions Cone Prewinder Weft sensor...

Page 15: ...nents when these are switched off disconnected from the mains and po tential free Z Z Prior to start up verify if all appropriate covers are mounted Z Z Prior to start up perform safety check WARNING...

Page 16: ......

Page 17: ...idity 5 90 non condensing Degree of protection IP50 Housing Chemical resistant made of conducting material Evaluation electronic Shielded against electrostatic or magnetic interference Sensor Optical...

Page 18: ......

Page 19: ...i 6 Spare Parts Article Designation Part No Optical yarn defects sensor Falcon i complete Optical yarn defects sensor Falcon i Carbon complete 46858000 46888000 Connecting plug 17153900 Cable 16958900...

Page 20: ...20 Spare Parts FALCON i Article Designation Part No IRO Connection cable 46326000 IRO Connection board 17160900 Mounting angle 33042000 Mounting bracket 43726000...

Page 21: ......

Page 22: ...Loepfe Brothers Ltd 8623 Wetzikon Switzerland Phone 41 43 488 11 11 Fax 41 43 488 11 00 info loepfe com www loepfe com Subject to technical modifications...

Reviews: