SMART TOUCH CON•X•US Interface

          

User’s Information Manual 

Figure 4-1 

Home Screen

w/Power-fin CON•X•US Interface

HOME

VIEW

SETUP

INFORMATION

SETTINGS

The Home Screen displays the available basic system information.  It is divided into the following sections:  Status, Demand, 
Modulation, Sensors, and Navigation.

• The 

Status

 Section is located on the top left of the screen 

 

and displays how the unit is currently running (i.e. Off, 

 

Stand-by, Blocking, and Lockout) including: current 

 

driving demand, the next Hot Water Setback scheduled, 

 

the reason for any blocking or lockout, and a power button.

• The 

Demand

 Section is located on the bottom left of the 

 

screen and displays information about the targets and 

 

limits of the current demand being serviced.

• The 

Modulation

 Section is located on the top right of the 

 

screen and displays the target modulation of the unit.  This 

 

section also includes target and actual fan speeds.

• The 

Sensor

 Section is located on the bottom right of the 

 

screen and displays both factory installed and field installed 

 

sensor including:  Outdoor Air, Hot Water Temperature, 

 

System Supply, System Return, Inlet Water, Delta T, Outlet 

 

Water, Flue Temperature, and Flame Current.

• The 

Navigation

 Section is located down the left side of the 

 

screen.  There are five (5) sections located below the 

 

Lochinvar icon:  Home, View, Setup, Information 

 

(About), and Settings.  The Home Section is the screen 

 

shown above.  The View Section provides more detailed 

 

information including subsections for:  History, Cascade, 

 

Graphing, and a complete list of current Sensor Values.  

 

The Setup Section has several screens to aid in setting 

 

up the appliance.  The Setup Section includes screens for 

 

adjusting:  Set Points, Pump Settings, Cascade, BMS, Ramp 

 

Delay, and Night Setback.   The Information Section 

 

provides information about the hardware and software 

 

including the current software version of the interface, the 

 

version of the boiler control, and the CON·X·US device 

 

serial number.  The Setting Section enables several interface 

 

setup features including:  Time Setup, Temperature Unit 

 

Select, Loch’n Link, System Update, and WiFi Setup.

Summary of Contents for Power-fin 1002

Page 1: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the i...

Page 2: ...tially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to perso...

Page 3: ...er can cause internal corrosion in system components Leaks in boiler or piping must be repaired at once to prevent the need for makeup water Freeze protection fluids NEVER use automotive antifreeze Us...

Page 4: ...s Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building cons...

Page 5: ...nd flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 Flame inspection stable uniform C...

Page 6: ...will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table 1A on page 4 of this manual If any of these products are in the room from which...

Page 7: ...wn boilers used for domestic water heating they must operate year round 3 Replace the front access door Test low water cutoff if installed 1 If the system is equipped with a low water cutoff test the...

Page 8: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety...

Page 9: ...e bottom right of the screen and displays both factory installed and field installed sensor including Outdoor Air Hot Water Temperature System Supply System Return Inlet Water Delta T Outlet Water Flu...

Page 10: ...10 Notes User s Information Manual...

Page 11: ...11 Notes User s Information Manual...

Page 12: ...reflects an update to the maintenance information for the service technician on page 5 Revision C PCP 3000028200 CN 500017830 reflects an update to the Home Screen information Revision D PCP 300003085...

Reviews: