Lochinvar Power-fin 1002 User'S Information Manual Download Page 3

      

User’s Information Manual 

Please read before proceeding

3

Installer – 

Read all instructions, 

including this manual and the Power-
fin Service Manual, before installing. 

 

Perform steps in the order given.

User – 

This manual is for use only 

by a qualified heating installer/
service technician.  Refer to the User’s 
Information Manual for your reference.
Have this boiler serviced/inspected by 
a qualified service technician, at least 
annually.
Failure to comply with the above could 
result in severe personal injury, death or 
substantial property damage.

Failure to adhere to the guidelines on this 
page can result in severe personal injury, 
death, or substantial property damage.

When servicing boiler –

• To avoid electric shock, disconnect electrical supply 
  before performing maintenance.
• To avoid severe burns, allow boiler to cool before 
 performing 

maintenance.

Boiler operation –

• Do not block flow of combustion or ventilation air to 
 the boiler.
• Should overheating occur or gas supply fail to shut off, 
 do not turn off or disconnect electrical supply to 
  circulator.  Instead, shut off the gas supply at a location 
  external to the appliance.

• Do not use this boiler if any part has been under water.  
  The possible damage to a flooded appliance can be 
  extensive and present numerous safety hazards.  Any 
  appliance that has been under water must be replaced.

Boiler water –

• 

Thoroughly flush the system (without boiler 

 connected) to remove sediment.  The high-efficiency 
 heat exchanger can be damaged by build-up or 
  corrosion due to sediment.
• 

Do not use petroleum-based cleaning or sealing 

  compounds in the boiler system.  Gaskets and seals in 
 the system may be damaged.  This can result in 
  substantial property damage.
• 

Do not use “homemade cures” or “boiler patent 

  medicines”.  Serious damage to the boiler, personnel, 
  and/or property may result.
• Continual fresh make-up water will reduce boiler life.  
 Mineral buildup in the heat exchanger reduces heat 
  transfer, overheats the heat exchanger, and causes failure.  
  Addition of oxygen carried in by makeup water can cause 
  internal corrosion in system components.  Leaks in boiler 
  or piping must be repaired at once to prevent the need for 
 makeup water.

Freeze protection fluids –

• NEVER use automotive antifreeze.  Use only inhibited 
 propylene glycol solutions, which are specifically 
  formulated for hydronic systems. Ethylene glycol is 
  toxic and can attack gaskets and seals used in hydronic 
 systems.

When calling or writing about the boiler 
– Please have the boiler model and serial 
number from the boiler rating plate.
Consider piping and installation when 
determining boiler location.
Any claims for damage or shortage in 
shipment must be filed immediately 
against the transportation company by 
the consignee.
Factory warranty (shipped with unit) does 
not apply to units improperly installed or 
improperly operated.

If the information in this manual is not 
followed exactly, a fire or explosion may 
result causing property damage, personal 
injury or loss of life.
This appliance MUST NOT be installed in 
any location where gasoline or flammable 
vapors are likely to be present.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do 
  not use any phone in your building.
• Immediately call your gas supplier 
  from a near by phone.  Follow the 
  gas supplier’s instructions.
• If you cannot reach your gas supplier, 
  call the fire department.
• 

Installation and service must be 

 performed by a qualified installer, 
  service agency, or the gas supplier.

 WARNING

 NOTICE

 WARNING

 WARNING

 WARNING

DO NOT install units in rooms or 
environments that contain corrosive 
contaminants (see Table 1A on page 4).  
Failure to comply could result in severe 
personal injury, death, or substantial 
property damage.

 WARNING

The California Safe Drinking Water and 
Toxic Enforcement Act requires the 
Governor of California to publish a list of 
substances known to the State of California 
to cause cancer, birth defects, or other 
reproductive harm, and requires businesses 
to warn of potential exposure to such 
substances.
This product contains a chemical known to 
the State of California to cause cancer, birth 
defects, or orther reproductive harm.  This 
boiler can cause low level exposure to some 
of the substances listed in the Act.

Summary of Contents for Power-fin 1002

Page 1: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the i...

Page 2: ...tially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to perso...

Page 3: ...er can cause internal corrosion in system components Leaks in boiler or piping must be repaired at once to prevent the need for makeup water Freeze protection fluids NEVER use automotive antifreeze Us...

Page 4: ...s Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building cons...

Page 5: ...nd flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 Flame inspection stable uniform C...

Page 6: ...will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table 1A on page 4 of this manual If any of these products are in the room from which...

Page 7: ...wn boilers used for domestic water heating they must operate year round 3 Replace the front access door Test low water cutoff if installed 1 If the system is equipped with a low water cutoff test the...

Page 8: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety...

Page 9: ...e bottom right of the screen and displays both factory installed and field installed sensor including Outdoor Air Hot Water Temperature System Supply System Return Inlet Water Delta T Outlet Water Flu...

Page 10: ...10 Notes User s Information Manual...

Page 11: ...11 Notes User s Information Manual...

Page 12: ...reflects an update to the maintenance information for the service technician on page 5 Revision C PCP 3000028200 CN 500017830 reflects an update to the Home Screen information Revision D PCP 300003085...

Reviews: